Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › Fibrinogen

Fibrinogen: Michigan Medicine Laboratories (MLabs) test FIB

Michigan Medicine Laboratories (MLabs) test FIB, CPT 85384. Specimen: Full 2.7mL tube or 1mL plasma aliquot. Turnaround: STAT 1 hour, Routine 4 hours.

Fibrinogen is Michigan Medicine Laboratories (MLabs) test code FIB, billed with CPT 85384. Specimen: Full 2.7mL tube or 1mL plasma aliquot. Turnaround time: STAT 1 hour, Routine 4 hours. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: Labcorp, Cleveland Clinic Laboratories, OHSU Laboratory Services, ARUP Laboratories, Allina Health Laboratory (Abbott Northwestern).
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeFIB
CPT85384
LOINC—
SpecimenFull 2.7mL tube or 1mL plasma aliquot
VolumeFull 2.7mL tube or 1mL plasma aliquot
Turnaround timeSTAT 1 hour, Routine 4 hours
Storage / transportRoom temperature for whole blood or frozen aliquot of citrated plasma.

Also known as: Clottable Fibrinogen; Fibrinogen Activity; Fibrinogen Level; Quantitative Fibrinogen

Use

Identification of congenital afibrinogenemia, disseminated intravascular coagulation, and fibrinolytic activity.

Collection instructions

Collect specimen in a blue top (citrate 3.2%) tube. Mix by inversion. Specimen should arrive at lab within 3 hours of collection; transport at room temperature. Alternatively, centrifuge, aliquot plasma into a plastic vial, and freeze the specimen within 4 hours of collection. Transport frozen specimen on dry ice. Collection of the blood through lines that have been previously flushed with heparin should be avoided. If the blood must be drawn through a VAD (vascular access device), the line should be flushed with 5 mL of saline and the first 5 mL of blood or six dead space volumes of the VAD discarded.

Reference range

150 - 450 mg/dL. Critical value:

Limitations

Increased in patients on oral contraceptives, pregnancy, or with active inflammatory processes. May be decreased in disseminated intravascular coagulation, severe liver disease, and congenital hypofibrinogenemia. Fibrinogen is insensitive to unfractionated heparin up to approximately 2 units/mL. Direct thrombin inhibitors (Argatroban, Bivalarudin, Dabigatran, etc.) in therapeutic doses with result in decreased fibrinogen levels.

Section

Coagulation

Performed

Daily, 24 hours

NY State approved

No

Performing Laboratory

Clinical Core Laboratory

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 85384

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation