Labcorp test 164530, CPT 85230, 85305. Specimen: Plasma, frozen. Turnaround: 5 - 7 days.

Protein S Antigen:Factor VII Antigen Ratio is Labcorp test code 164530, billed with CPT 85230, 85305. Specimen: Plasma, frozen. Turnaround time: 5 - 7 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code164530
CPT85230; 85305
LOINC27823-4, 49870-9, 8251-1
SpecimenPlasma, frozen
Volume2 mL
Minimum volume1 mL ( Note: This volume does not allow for repeat testing.)
ContainerBlue-top (sodium citrate) tube
Turnaround time5 - 7 days
Storage / transportFreeze; five freeze/thaw cycles are acceptable. Stable at room temperature or refrigerated for four hours.

Test includes

This test includes protein S antigen, total; factor VII antigen; and calculated ratio of protein S to factor VII antigen.

Use

This profile is used to measure total protein S antigen, factor VII antigen and the ratio of protein S antigen to factor VII antigen.

Methodology

See individual tests.

Collection instructions

Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples unless the sample is collected using a winged (butterfly) collection system. With a winged blood collection set, a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternative anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.

Patient preparation

Do not draw from an arm with a heparin lock or heparinized catheter.

Reference range

Protein S , Total Age Range 0 to 6 m 12–60% >6 m 60–140% Factor VII Antigen 59–178% Protein S/Factor VII Antigen Ratio 0.5–2.2

Limitations

This assay may not detect rare qualitative types of protein S deficiency. Results of this ratio should be confirmed once the patient is off warfarin. The component test, factor VII antigen, was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
Protein S, Total%27823-4
Factor VII Antigen%49870-9
Prt S/FVII Ag Ratioratio8251-1

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 85230, 85305

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation