Protein S Antigen: Labcorp test 164517
Labcorp test 164517, CPT 85305, 85306. Specimen: Plasma, frozen. Turnaround: 2 - 3 days.
Test includes
This test includes protein S, total; and protein S, free.
Use
This test is used for confirmation and characterization of protein S (PS) congenital deficiency.
Methodology
Total and free PS antigens are measured by latex immunoassay.
Collection instructions
Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples, except when using a winged blood collection device (i.e., "butterfly"), in which case a discard tube should be used. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove / 3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap, and recentrifuge for 10 minutes. Use a second plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Stability
| Temperature | Period |
|---|---|
| Frozen | 28 days |
| Freeze/thaw cycles | Stable x3 |
Patient preparation
Avoid warfarin (Coumadin®) therapy for two weeks and heparin therapy for two days prior to the test. Do not draw from an arm with a heparin lock or heparinized catheter.
Causes for rejection
Gross hemolysis; clotted specimen; frozen specimen thawed in transit; improper labeling
Reference range
Protein S Antigen Age Range 0 to 6 m 12–60% >6 m 60–140% Total: In newborns, total PS levels are lower than in adults (12% to 60%). Levels gradually reach adult ranges by six months of age.
Special instructions
If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions.
Limitations
The presence of rheumatoid factor at a level greater than 300 IU/mL may lead to an over-estimation of the total protein S level. The presence of anti-rabbit antibodies in certain subjects leads to aberrant results.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 164518 | Protein S, Total | % | 27823-4 |
| 164519 | Protein S, Free | % | 27821-8 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 85305, 85306
- Protein C and S Panel, Total, Antigen
- Protein C, Functional with Reflex to Protein C, Total and Protein S, Free with Reflex to Protein S, Total
- Protein S Antigen:Factor VII Antigen Ratio
- Protein S Deficiency Profile
- Protein S, Free Antigen with Reflex to Protein S, Total Antigen
- Protein S, Total Antigen
- Protein S Deficiency Profile
- Protein S Deficiency Profile
- Protein C and S Panel, Functional
- Protein S Clottable
- Protein S Free Immunologic
- Protein S Free, Antigen
- Protein S, Free
- Protein S, Functional
- Protein S, Functional
- Thrombotic Risk Assessment
- Thrombotic Risk Reflex Panel
- Thrombotic Risk, Congenital
- Thrombotic Risk, Congenital (Extended)
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation