Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Factor VIII Activity, Chromogenic

Factor VIII Activity, Chromogenic: Labcorp test 086295

Labcorp test 086295, CPT 85230. Specimen: Plasma, frozen. Turnaround: 3 - 5 days.

Factor VIII Activity, Chromogenic is Labcorp test code 086295, billed with CPT 85230. Specimen: Plasma, frozen. Turnaround time: 3 - 5 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code086295
CPT85230
LOINC3211-0
SpecimenPlasma, frozen
Volume1 mL
ContainerBlue stopper 3.2% sodium citrate plasma evacuated tube
Turnaround time3 - 5 days
Storage / transportFreeze.

Also known as: Antihemophilic Factor (AHF)

Use

This test is used in the measurement of factor VIII activity in hemophilia patients. The chromogenic assay can be used in place of the more commonly used one-stage assay (OSA) for a number of clinical indications where limitations of OSA require a secondary option for FVIII testing.

Methodology

The FVIII chromogenic substrate assay measures the FVIII-dependent activation of FX using purified bovine coagulation factors. This test consists of two steps. In the first step, patient plasma is added to a reaction mixture containing FIXa, FX, calcium ions, phospholipids and trace amounts of thrombin. Thrombin triggers the activation of FVIII and the subsequent FIXa-mediated activation of FX. FXa production is proportional to the concentration of FVIII in the plasma samples. In the second step, the amount of FXa produced is quantified using a chromogenic peptide substrate that binds selectively to FXa.

Collection instructions

Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge and carefully remove the plasma using a plastic transfer pipette, being careful not to disturb the cells. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested . Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.

Patient preparation

Ideally the patient should not be on anticoagulant therapy. Avoid warfarin (Coumadin®) therapy for two weeks prior to the test and heparin, direct Xa and thrombin inhibitor therapies for about three days prior to testing. Do not draw from an arm with a heparin lock or heparinized catheter.

Reference range

49–126%

Special instructions

If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions.

Limitations

Factor VIII is an acute phase reactant and can be elevated in a number of clinical conditions. This can affect the accuracy of the test in diagnosing hemophilia. Factor VIII levels should not be used to determine the carrier status of females. Genetic testing should be used for this purpose. Factor VIII inhibitors (both autoantibodies that develop after replacement therapy and autoantibodies that develop spontaneously) can result in low factor VIII levels. A lupus anticoagulant may cause factor VIII activity to appear spuriously low, and a chromogenic factor VIII activity is recommended in this circumstance. Direct Xa inhibitor therapy may cause factitiously low results. This test was…

LOINC map

Result codeResult nameUnitsResult LOINC
086296Factor VIII Act, Chromogenic%3211-0

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 85230

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation