Factor VII Activity With Inhibitor Reflex: Labcorp test 086252

Labcorp test 086252, CPT 85230. Specimen: Plasma, frozen. Turnaround: 5 - 7 days.

Factor VII Activity With Inhibitor Reflex is Labcorp test code 086252, billed with CPT 85230. Specimen: Plasma, frozen. Turnaround time: 5 - 7 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code086252
CPT85230
LOINC3198-9
SpecimenPlasma, frozen
Volume2.0 mL
Minimum volume1.0 mL ( Note: This volume does not allow for repeat testing.)
ContainerBlue-top (sodium citrate) tube
Turnaround time5 - 7 days
Storage / transportFreeze.

Also known as: Factor VII Inactivator; Factor VII Bethesda Titer

Test includes

This test includes factor VII activity with reflex to factor VII Inhibitor (Bethesda titer) when activity is less than or equal to 40%.

Use

This profile measures factor VII activity and reflexes to a measurement of factor VII inhibitor level (Bethesda titer) when the activity level is diminished to 40% or less.

Methodology

See individual activity test information for method information. The Bethesda titer measures the amount (titer) of an inhibitor antibody against a specific clotting factor. The test uses dilutions of the patient's plasma and determines the amount of antibody needed to neutralize 50% of the factor activity provided by pooled normal plasma with results expressed in Bethesda units (BUs). One Bethesda Unit (BU) is defined as the amount of an inhibitor that will neutralize 50% of one unit of the factor in normal plasma after 120 minutes incubation at 37°C. A higher titer indicates a stronger inhibitor, which can significantly impact treatment. A Bethesda titer assay is not performed when factor…

Collection instructions

Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples unless the sample is collected using a winged (butterfly) collection system. With a winged blood collection set, a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternative anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.

Stability

TemperaturePeriod
Frozen28 days
Freeze/thaw cyclesStable x3

Patient preparation

Ideally, the patient should not be on anticoagulant therapy. Avoid warfarin (Coumadin®) therapy for two weeks prior to the test and heparin, direct Xa and thrombin inhibitor therapies for about three days prior to testing. Do not draw from an arm with a heparin lock or heparinized catheter.

Causes for rejection

Severe hemolysis; improper labeling; clotted specimen; specimen diluted with IV fluids; samples thawed in transit; improper sample type; sample out of stability

Reference range

Age Range 1 d 52–88% 3 d 67–107% 1 to 11 m 83–160% 1 to 5 y 72–150% 6 to 10 y 70–156% 11 to 16 y 69–170% >16 y 55–170%

Special instructions

If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions.

Limitations

This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
800599Factor VII Activity%3198-9

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 85230

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation