Factor VII Activity: Labcorp test 800599
Labcorp test 800599, CPT 85230. Specimen: Plasma, frozen. Turnaround: 2 - 3 days.
Also known as: Proconvertin
Use
This test is used to evaluate an isolated prolonged PT and document factor VII deficiency.
Methodology
Factor VII activity is determined utilizing a prothrombin time (PT)-based one-stage clotting time assay. Factor VII-depleted plasma is used as the substrate, and the clotting time with the patient plasma is compared to the clotting time of normal pooled plasma. The assay consists of the measurement of the clotting time in a system in which all the factors are present and in excess except factor VII, which is derived from the sample being tested. Testing coagulation factor activities requires that three dilutions be assayed and analyzed to produce a single result. The slope of the line created by plotting measured factor concentration against sample dilution is evaluated to discern the…
Collection instructions
Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples unless the sample is collected using a winged (butterfly) collection system. With a winged blood collection set a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternative anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Stability
| Temperature | Period |
|---|---|
| Frozen | 28 days |
| Freeze/thaw cycles | Stable x2 |
Patient preparation
Ideally, the patient should not be on anticoagulant therapy. Avoid warfarin (Coumadin®) therapy for two weeks prior to the test and heparin, direct Xa and thrombin inhibitor therapies for about three days prior to testing. Do not draw from an arm with a heparin lock or heparinized catheter.
Causes for rejection
Gross hemolysis; clotted specimen; frozen specimen thawed in transit; improper labeling
Reference range
Factor VII Activity Age Range 1 d 52–88% 3 d 67–107% 1 to 11 m 83–160% 1 to 5 y 72–150% 6 to 10 y 70–156% 11 to 16 y 69–170% >16 y 55–170%
Special instructions
If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions.
Limitations
Direct Xa or thrombin inhibitor therapy may cause factitiously low results. Artifactual elevations in factor VII can occur as the result of cold activation of factor VII in the collection tube prior to analysis. Refrigerating or placing on ice for an extended period prior to freezing the plasma can result in the conversion of factor VII to activated factor VIIa.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 800599 | Factor VII Activity | % | 3198-9 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 85230
- Bethesda Inhibitor
- Extrinsic Pathway Coagulation Factor Profile
- Factor VII Activity With Inhibitor Reflex
- Factor VII Antigen
- Factor VII Assay
- Factor VII, Activity
- Factor VIII Activity, Chromogenic
- Prolonged Clot Time Reflexive Profile
- Prolonged Protime Profile
- Protein C Antigen:Factor VII Antigen Ratio
- Protein S Antigen:Factor VII Antigen Ratio
- Prolonged Protime Profile
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation