Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Protein S Deficiency Profile

Protein S Deficiency Profile (Spe): Labcorp test 117754

Labcorp test 117754, CPT 85305, 85306. Specimen: Plasma, frozen. Turnaround: 2 - 3 days.

Protein S Deficiency Profile is Labcorp test code 117754, billed with CPT 85305, 85306. Specimen: Plasma, frozen. Turnaround time: 2 - 3 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code117754 (Spe)
CPT85305; 85306(x2)
LOINC27821-8, 27822-6, 27823-4, 87557-5
SpecimenPlasma, frozen
Volume1 mL
ContainerBlue-top (sodium citrate) tube
Turnaround time2 - 3 days
Storage / transportFreeze.

Test includes

This test includes Protein S, free; protein S, functional; and protein S, total.

Use

This test is used for confirmation and characterization of protein S (PS) congenital deficiency.

Methodology

Total PS and free PS antigen: Total PS and free PS antigens are measured by latex immunoassay (IA). PS activity: The patient plasma is added to PS-depleted normal plasma with normal levels of all factors but PS. The mixture is supplemented with excess aPC, and factor V is then added. The extent of prolongation of the time to clot formation after calcium chloride is added is proportional to plasma PS activity.

Collection instructions

Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples, except when using a winged blood collection device (ie, "butterfly"), in which case a discard tube should be used. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove / 3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap, and recentrifuge for 10 minutes. Use a second plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.

Stability

TemperaturePeriod
Frozen28 days
Freeze/thaw cyclesStable x3

Patient preparation

Avoid warfarin (Coumadin®) therapy for two weeks and heparin therapy for two days prior to the test. Do not draw from an arm with a heparin lock or heparinized catheter.

Causes for rejection

Gross hemolysis; clotted specimen; frozen specimen thawed in transit; improper labeling

Special instructions

If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions.

Limitations

The presence of heparin or lupus anticoagulants leads to overestimation of PS. aPC resistance due to factor V Leiden mutation or some other cause can falsely lower measured PS activity levels.

LOINC map

Result codeResult nameUnitsResult LOINC
164518Protein S, Total%27823-4
164519Protein S, Free%27821-8
164526Protein S-Functional%27822-6

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 85305, 85306

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation