Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Allina Health Laboratory (Abbott Northwestern) › Von Willebrand screen

Von Willebrand screen: Allina Health Laboratory (Abbott Northwestern) test 507

Allina Health Laboratory (Abbott Northwestern) test 507, CPT 85240, 85245, 85246, 86327. Specimen: Sodium citrate (Na cit) plasma. Turnaround: 1 - 3 days.

Von Willebrand screen is Allina Health Laboratory (Abbott Northwestern) test code 507, billed with CPT 85240, 85245, 85246, 86327. Specimen: Sodium citrate (Na cit) plasma. Turnaround time: 1 - 3 days. Performing laboratory: Allina Health Laboratory (Abbott Northwestern), CLIA 24D0401558 (Minneapolis, MN). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Labcorp, ARUP Laboratories, Michigan Medicine Laboratories (MLabs), OHSU Laboratory Services.
LaboratoryAllina Health Laboratory (Abbott Northwestern)
CLIA number24D0401558
Test code507
CPT85246; 85245; 85240; Additional CPT codes (if appropriate):; 86327 - von Willebrand multimer studies
LOINC—
SpecimenSodium citrate (Na cit) plasma
VolumeFour (4) full 2.7mL tubes
Minimum volumeTwo (2) full 2.7mL tubes
ContainerLt blue Sodium citrate (Na Cit) - 2.7mL x 4 If the patient has a hematocrit >55, a specially prepared Lt blue Sodium citrate (NaCit) tube must be used in place of the standard Lt blue Sodium citrate (NaCit) tube. Hematocrit-Anticoagulant adjustments
Turnaround time1 - 3 days

Also known as: VWF activity; VWF antigen; Von Willebrands complex; Tests included:; Reflex criteria:; Decrease in the VWF:Act and/or the VWF:Agn results will automatically reflex to von Willebrand multimers, referred to Mayo, at an additional charge.; Limitations:; HemosIL von Willebrands Factor activity assay is an antibody-based assay (vWF:Ab) that uses specific anti-VWF monoclonal antibody directed against the platelet-binding site of VWF (glycoprotein Ib receptor) adsorbed onto latex reagent particles which react with the VWF of patient plasma. The degree of agglutination is directly proportional to the activity of VWF in the sample. The clinical sensitivity of the vWF:Ab assay is similar to aggregometry based vWF:RCo (Ristocetin cofactor) assays in screening for congenital vWD and has an apparently improved sensitivity for acquired von Willebrand’s syndrome (AVWS). Additional evaluation including multimer testing is necessary for subclassification of vWD types.

Methodology

vWF:Act - Immunoturbidimetry VWF:Ag - Immunoturbidimetry FVIII: Clotting

Collection instructions

Do not over or under fill tube as the ratio of anticoagulant to whole blood is critical Coag – tube fill guidelines Immediatley following collection, mix sample thoroughly by gentle inverting 8 - 10 times, to prevent clotting

Stability

Frozen - strict Multimer samples are stabile for 14 days at -70°. Refrigerated - NO

Causes for rejection

Samples collected in Greiner tubes Improper labeling (unlabeled or mislabeled) Improper anticoagulant Improperly filled (over or underfilled) tube Hemolysis Clotted specimen Delay in transport Improper storage/transport temperature Patient on heparin > 1.0 IU/mL.

Reference range

Component Range vWF:Act 50 - 200% vWF:AG 50 - 200% FVIII:C 55 - 200% vWF: Act/vWF:AG >0.7 Von Willebrand factor activity levels are blood group specific with individuals of 'O' blood type showing lower von Willebrand activity levels than other blood groups.

Performed

Mo, We, Fr

Abbreviation

VWI

Order number

LAB507

Transport container

Microcentrifuge vial/tube in a Snap cap conical vial/tube and cap (Beaker sites) Coagulation specimen transport vial/tube (all other sites)

Performing Laboratory

AHL - Coagulation/Special Coagulation: V

Processing instructions

Process Platelet Poor Plasma (P.P.P) Coag – how to prepare a specimen for special coagulation testing Transfer plasma into a Microcentrifuge vial/tube (Beaker sites) or Coagulation specimen transport vial/tube (all other sites), labeled as platelet poor plasma Freeze immediately, or within two (2) hours of sample collection

View this test on Allina Health Laboratory (Abbott Northwestern)'s website → · Last checked 2026-11-29

Other tests billed with CPT 85240, 85245, 85246

Search the National Lab Test Directory · All Allina Health Laboratory (Abbott Northwestern) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation