Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Factor VIII Activity With Inhibitor Reflex

Factor VIII Activity With Inhibitor Reflex: Labcorp test 086010

Labcorp test 086010, CPT 85240. Specimen: Plasma, frozen. Turnaround: 5 - 7 days.

Factor VIII Activity With Inhibitor Reflex is Labcorp test code 086010, billed with CPT 85240. Specimen: Plasma, frozen. Turnaround time: 5 - 7 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code086010
CPT85240 85 335 85 240 Synonyms Factor VIII Inactivator Factor VIII Bethesda Titer
LOINC3209-4
SpecimenPlasma, frozen
Volume2.0 mL
Minimum volume1.0 mL ( Note: This volume does not allow for repeat testing.)
ContainerBlue-top (sodium citrate) tube
Turnaround time5 - 7 days
Storage / transportFreeze.

Test includes

This test includes factor VIII activity with reflex to factor VIII inhibitor (Bethesda titer) when activity is less than or equal to 40%.

Use

This profile measures factor VIII activity and reflexes to a measurement of factor VIII inhibitor level (Bethesda titer) when the activity level is diminished below 40%.

Methodology

See individual activity test information for method information. The Bethesda titer measures the amount (titer) of an inhibitor antibody against a specific clotting factor. The test uses dilutions of the patient's plasma and determines the amount of antibody needed to neutralize 50% of the factor activity provided by pooled normal plasma with results expressed in Bethesda units (BUs). One Bethesda Unit (BU) is defined as the amount of an inhibitor that will neutralize 50% of one unit of the factor in normal plasma after 120 minutes incubation at 37°C. A higher titer indicates a stronger inhibitor, which can significantly impact treatment. A Bethesda titer assay is not performed when factor…

Collection instructions

Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge and carefully remove the plasma using a plastic transfer pipette, being careful not to disturb the cells. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested . Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.

Stability

TemperaturePeriod
Frozen28 days
Freeze/thaw cyclesStable x3

Patient preparation

Ideally the patient should not be on anticoagulant therapy. Avoid warfarin (Coumadin®) therapy for two weeks prior to the test and heparin, direct Xa and thrombin inhibitor therapies for about three days prior to testing. Do not draw from an arm with a heparin lock or heparinized catheter.

Causes for rejection

Severe hemolysis; improper labeling; clotted specimen; specimen diluted with IV fluids; samples thawed in transit; improper sample type; sample out of stability

Special instructions

If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions.

Limitations

This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
Factor VIII Activity%3209-4

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 85240

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation