Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › OHSU Laboratory Services › Factor VIII Activity

Factor VIII Activity: OHSU Laboratory Services test LAB00256

OHSU Laboratory Services test LAB00256, CPT 85240. Specimen: 3.2% sodium citrate tubes are acceptable when they are filed to the line on the manufacturers label. Tubes must be full . Turnaround: 4 Hours.

Factor VIII Activity is OHSU Laboratory Services test code LAB00256, billed with CPT 85240. Specimen: 3.2% sodium citrate tubes are acceptable when they are filed to the line on the manufacturers label. Tubes must be full (see comments below). Turnaround time: 4 Hours. Performing laboratory: OHSU Laboratory Services, CLIA 38D0676694 (Portland, OR). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Labcorp, ARUP Laboratories, Michigan Medicine Laboratories (MLabs), Allina Health Laboratory (Abbott Northwestern).
LaboratoryOHSU Laboratory Services
CLIA number38D0676694
Test codeLAB00256
CPT85240 x 1 (Factor VIII Coag)
LOINC—
Specimen3.2% sodium citrate tubes are acceptable when they are filed to the line on the manufacturers label. Tubes must be full (see comments below). For referral testing, submit 2 x 1.0 mL frozen platelet poor citrated plasma. Sodium citrate specimens must be processed and frozen within 1 hours of specimen collection. OHSU clinics must cab specimen to the Core Lab, Hatfield Research Center (HRC), Room 9D05 if processing is delayed or not possible on site. A phone call is helpful to alert the lab at 503-494-5764. Detailed instructions are under the Hemostasis & Thrombosis section (Opens in a new window) .
Turnaround time4 Hours

Also known as: F8A; Factor 8; Factor VIII; FVIIIA

Test includes

Assay is included in the Von Willebrand Panel.

Reference range

Reference Range: 50% to 150%

Special instructions

Draw volume is critical due to the liquid anticoagulant. Allow tubes to fill by vacuum. Tubes with rubber stopper: fill to line on label. Tubes with plastic (Hemogard) cap: the fill level is above the top of the label. Syringe: do not remove the vacutainer stopper. Insert the needle through the stopper and allow the tube to fill by vacuum. Do not overfill the vacutainer. Pediatric tubes have no vacuum. Remove the cap and add blood to the 1.3 mL mark. Do not overfill. Avoid warfarin (Coumadin) therapy for 2 weeks and heparin therapy for 2 days prior to the test. Use: detect coagulant factor VIII deficiency. Factor VIII deficiency (Hemophilia A) is the most common of the hereditary bleeding disorders. Deficiences of factor VIII are inherited as sex-linked recessive disorders. Factor VIII is a molecular complex consisting of VIII:C, which corrects the abnormal clotting time, and VIII:R the "related protein" (the von Willebrand protein) which corrects the defect in von Willebrand disease. VIII:C portion of the complex is a glycoprotein with molecular weight of about 285,000. There are both VIII:C deficient patients (CRM-type also named hemophilia A-, the common form) and VIII:C nonfunctional molecular variant patients (CRM+ type also named hemophilia A+). Female patients with VWD on oral contraceptives or who are pregnant may have normal F. VIII values. F. VIII is also an acute-phase reactant and is elevated with stress or exercise.

Units

%

Section

Core Lab

Performed

24 hours, 7 days a week.

Pediatric specimen

Add blood to the 1.3 mL mark of Pediatric BLUE top tube, 3.2% sodium citrate. Pediatric tubes are acceptable when they are filed to the line on the manufacturers label. For pediatric patients requiring multiple coagulation tests, please call 503-494-7383 regarding draw volumes.

View this test on OHSU Laboratory Services's website → · Last checked 2026-11-29

Other tests billed with CPT 85240

Search the National Lab Test Directory · All OHSU Laboratory Services tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.