Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › TERT Promoter Mutation (Tissue)

TERT Promoter Mutation (Tissue): Michigan Medicine Laboratories (MLabs) test TERT

Michigan Medicine Laboratories (MLabs) test TERT, CPT 81345, 88381. Specimen: Formalin-fixed, paraffin-embedded tissue, Diff-Quik stained aspirate smear. Extracted DNA is also acceptable if extracte. Turnaround: 3 – 10 days.

TERT Promoter Mutation (Tissue) is Michigan Medicine Laboratories (MLabs) test code TERT, billed with CPT 81345, 88381. Specimen: Formalin-fixed, paraffin-embedded tissue, Diff-Quik stained aspirate smear. Extracted DNA is also acceptable if extracted in a CLIA certifie. Turnaround time: 3 – 10 days. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: Labcorp.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeTERT
CPT81345, 88381-TC
LOINC—
SpecimenFormalin-fixed, paraffin-embedded tissue, Diff-Quik stained aspirate smear. Extracted DNA is also acceptable if extracted in a CLIA certified laboratory.
VolumeFormalin-fixed, paraffin-embedded tissue, Diff-Quik stained aspirate smear. Extracted DNA is also acceptable if extracted in a CLIA certified laboratory.
Turnaround time3 – 10 days

Use

TERT (telomerase reverse transcriptase) is involved in maintaining the length of chromosome telomeres. The TERT gene is normally expressed in germ cells and stem cells but is repressed in postnatal somatic cells. Because chromosomes are shortened with each round of DNA replication, cells without telomerase activity have a limited number of divisions before apoptosis occurs. Telomerase activity, therefore, plays an important role in immortalizing the cells of many types of cancer. A common mechanism of increased telomerase activity in cancer is mutation of the TERT promoter. These mutations create a consensus binding site for ETS transcription factors leading to increased TERT expression.…

Collection instructions

For formalin-fixed, paraffin-embedded tissue, a block containing an area with a high percentage of neoplastic cells (for micro-/macro-dissection) is preferred. Unstained, UNBAKED slides (5-8, 10-micron slides; 10-15 if few neoplastic cells are present) with associated H&E stained slide are also acceptable. Decalcified tissue or other fixatives will be accepted and the assay attempted, however these may result in failed testing due to degraded nucleic acid. Both blocks and slides should be stored at room temperature. A Diff-Quik stained aspirate smear (preferably containing a high percentage and overall amount of neoplastic cells) is also acceptable. Store at room temperature.

Reference range

Interpretive report provided.

Limitations

A negative result does not rule out the presence of a rare mutation or a mutation below the limit of detection (5% mutant allele). In addition, the absence of a TERT promoter mutation does not exclude malignancy or malignant potential.

Section

Molecular Diagnostics

Performed

Monday - Friday

NY State approved

No

Alternate specimens

Slides will be accepted: send 8 unbaked, unstained slides (10 micron) and 1 H&E stained slide.

Performing Laboratory

Molecular Diagnostics

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 81345, 88381

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation