KRAS Mutation in Malignancy: Michigan Medicine Laboratories (MLabs) test KRAS

Michigan Medicine Laboratories (MLabs) test KRAS, CPT 81275, 81276, 88381. Specimen: Formalin-fixed, paraffin-embedded tissue; Diff-Quik stained aspirate smear, Papanicolaou stained aspirate smear. Extract. Turnaround: 7 - 21 days.

KRAS Mutation in Malignancy is Michigan Medicine Laboratories (MLabs) test code KRAS, billed with CPT 81275, 81276, 88381. Specimen: Formalin-fixed, paraffin-embedded tissue; Diff-Quik stained aspirate smear, Papanicolaou stained aspirate smear. Extracted DNA is also accep. Turnaround time: 7 - 21 days. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Labcorp, Cleveland Clinic Laboratories.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeKRAS
CPT81275, 81276, 88381-TC
LOINC—
SpecimenFormalin-fixed, paraffin-embedded tissue; Diff-Quik stained aspirate smear, Papanicolaou stained aspirate smear. Extracted DNA is also acceptable if extracted in a CLIA certified laboratory.
VolumeFormalin-fixed, paraffin-embedded tissue; Diff-Quik stained aspirate smear, Papanicolaou stained aspirate smear. Extracted DNA is also acceptable if extracted in a CLIA certified laboratory.
Turnaround time7 - 21 days

Also known as: K-RAS Mutation Detection

Use

Activating mutations in the KRAS gene occur in approximately 40% of colorectal carcinomas, 20% of non-small cell lung cancers, and a variety of other human cancers. Mutations are predominantly single nucleotide substitutions (missense mutations), most frequently occurring within codons 12 and 13 of exon 2. Less commonly, mutations occur within codon 61 of exon 3 and codons 117 and 146 of exon 4. Collectively these mutations have been associated with a limited clinical response to epidermal growth factor receptor (EGFR) targeted therapies in lung and colorectal cancers, and may also have prognostic implications. This DNA test is performed by targeted next-generation sequencing to detect…

Collection instructions

For formalin-fixed, paraffin-embedded tissue, a block containing an area with a high percentage of neoplastic cells (for micro-/macro-dissection) is preferred. Unstained, UNBAKED slides (5-8, 10-micron slides; 10-15 if few neoplastic cells are present) with associated H&E stained slide are also acceptable. Decalcified tissue or other fixatives will be accepted and the assay attempted, however these may result in failed testing due to degraded nucleic acid. Both blocks and slides should be stored at room temperature. A Diff-Quik or Papanicolaou stained aspirate smear (preferable containing a high percentage and overall amount of neoplastic cells) is also acceptable. Store at room temperature.

Reference range

Interpretive report provided.

Limitations

This test does not detect copy number variants or translocations and may not detect large insertions, deletions or duplications. This test may also fail to detect mutations below the limit of detection of this assay (approximately 5%). Rare polymorphisms may lead to false negative results. Discordant results are rarely observed between metastatic and primary specimens. The clinical implications of the findings as indicated in the test report may change based on evolution of the scientific literature. This test is for the purpose of detecting somatic mutations in neoplastic tissue. While this test cannot definitively distinguish between somatic and germline variants, know germline variants…

Section

Molecular Diagnostics

Performed

Monday - Thursday

NY State approved

No

Alternate specimens

For exhausted formalin-fixed, paraffin-embedded blocks, the original Hematoxylin and Eosin stained slide(s) may be extracted at the discretion of the Molecular Diagnostics Laboratory Director. The extraction process will result in destruction of the slide(s). A digital image of the slide(s) must be collected prior to extraction and retained for a minimum of 10 years from the specimen collection date. Previously extracted DNA may be accepted; however, the extracting laboratory must take responsibility for ensuring that viable, neoplastic cells comprise at least 20% of cellularity within the extracted sample

Performing Laboratory

Molecular Diagnostics

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 81275, 81276, 88381

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation