Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › KRAS Gene Mutation Analysis, IVD

KRAS Gene Mutation Analysis, IVD (Onc): Labcorp test 480875

Labcorp test 480875, CPT 81275, 88381. Specimen: Formalin-fixed, paraffin-embedded (FFPE) tissue block or slides from colorectal cancer or NSCLC. Turnaround: 5 - 7 days.

KRAS Gene Mutation Analysis, IVD is Labcorp test code 480875, billed with CPT 81275, 88381. Specimen: Formalin-fixed, paraffin-embedded (FFPE) tissue block or slides from colorectal cancer or NSCLC. Turnaround time: 5 - 7 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code480875 (Onc)
CPT81275; 88381
LOINC21703-4, 48004-6, 57723-9
SpecimenFormalin-fixed, paraffin-embedded (FFPE) tissue block or slides from colorectal cancer or NSCLC
VolumeFour unstained slides and one matching H&E-stained slide at 5 μM or formalin-fixed, paraffin-embedded tissue block
Minimum volumeTwo unstained slides and one matching H&E-stained slide at 5 μM. Samples with >4 mm² and ≥20% tumor content are preferred.
ContainerSlides, blocks
Turnaround time5 - 7 days
Storage / transportMaintain specimen at room temperature up to 4 weeks at 15-30°C.

Use

The therascreen KRAS RGQ PCR Kit is a real-time qualitative PCR assay used on the Rotor-Gene Q MDx (US) instrument for the detection of 7 somatic mutations in the human KRAS oncogene using DNA extracted from formalin fixed paraffin embedded (FFPE) colorectal cancer (CRC) tissue and non-small cell lung cancer (NSCLC) tissue. The therascreen KRAS RGQ PCR Kit is intended to aid in the identification of CRC patients for treatment with Erbitux® (cetuximab) or with Vectibix® (panitumumab) based on a KRAS No Mutation Detected test result. The therascreen KRAS RGQ PCR Kit is also intended to aid in the identification of NSCLC patients for treatment with LUMAKRAS™ (sotorasib) based on a KRAS G12C…

Methodology

Amplification refractory mutation system (ARMS) and real-time polymerase chain reaction (PCR) using Scorpions™ technology

Causes for rejection

Tumor block containing no tumor tissue; tumor fixed in a heavy metal fixative; broken or stained slides

Special instructions

Please provide a copy of the pathology report. Direct any questions regarding this test to customer service at 800-345-4363.

Limitations

Based on data in the COSMIC database (2012 v59), the seven mutations detected by the KRAS Kit account for >97% of all reported KRAS mutations in CRC patients. The KRAS G12C mutation is estimated to be present in around 13% of NSCLC cases. Samples with results reported as "no mutation detected" may harbor KRAS mutations that are not detected by the assay. Detection of mutation is dependent on sample integrity and the amount of amplifiable DNA present in the specimen. The methods used in this assay are highly selective and, depending on the total amount of DNA present, can detect approximately 1% to 5% of mutant DNA in a background of wild-type genomic DNA.

Disease

Colorectal cancer (CRC) Lung Non-small cell lung cancer (NSCLC)

Technology

Molecular

LOINC map

Result codeResult nameUnitsResult LOINC
KRAS Mutation Analysis, IVD480877Block Number:57723-9
KRAS Mutation Analysis, IVD480907Nucleotide Change:48004-6
KRAS Mutation Analysis, IVD480908Background:21703-4

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 81275, 88381

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation