Sound Lab Consultants › National Lab Test Directory › Labcorp › Microsatellite Instability Analysis

Microsatellite Instability Analysis (Onc): Labcorp test 570149

Labcorp test 570149, CPT 81301, 88381. Specimen: One paraffin-embedded tumor and either whole blood or paraffin-embedded normal tissue. Turnaround: 10 - 14 days.

Microsatellite Instability Analysis is Labcorp test code 570149, billed with CPT 81301, 88381. Specimen: One paraffin-embedded tumor and either whole blood or paraffin-embedded normal tissue. Turnaround time: 10 - 14 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code570149 (Onc)
CPT81301; 88381
LOINC18781-5, 39111-0
SpecimenOne paraffin-embedded tumor and either whole blood or paraffin-embedded normal tissue
VolumeEight unstained slides at 5 μM and one matching H&E slide or FFPE tissue block or 3-5 mL whole blood
Minimum volumeSamples with ≥4 mm² tumor and normal tissue surface area and ≥50% tumor content are preferred; 3 mL whole blood
ContainerFFPE tissue block or slides, lavender-top (EDTA) tube or green-top (sodium heparin) tube, tan-top (K2-EDTA) tube or pink-top (K2-EDTA) tube
Turnaround time10 - 14 days
Storage / transportBlocks and slides at room temperature; whole blood at 2°C to 8°C

Also known as: Colorectal Cancer Screening; Hereditary Nonpolyposis Colorectal Cancer, Screening; Mismatch Repair Defect; Replication Repair (RER)

Use

This test is used to identify tumors with microsatellite instability. High-frequency microsatellite instability (MSI-H) is associated with Lynch syndrome, but it is also found in 15% to 20% of sporadic colorectal and endometrial cancers. Lynch syndrome is an autosomal-dominant inherited cancer syndrome that predisposes to colorectal, endometrial, gastric, ovarian, upper urinary tract and other cancers. MSI-H status may enhance the likelihood of tumor responsiveness to immune checkpoint inhibitor therapy.

Methodology

Multiplex polymerase chain reaction (PCR); capillary electrophoresis

Causes for rejection

Tumor block containing insufficient tumor tissue or no tumor; broken or stained slides. Whole blood: Contaminated specimen; frozen whole blood received; leaking tube; clotted blood; hemolysis; specimen containing suspicious foreign material; quantity not sufficient for analysis

Special instructions

This assay needs both (1) DNA prepared from FFPE (formalin-fixed and paraffin-embedded) tumor tissue and (2) matched normal tissue (FFPE or blood). Please provide a copy of the pathology report. This test will be delayed if the pathology report is not received. Please direct any questions regarding this test to customer service at 800-345-4363.

Limitations

MSI-H is a marker of underlying DNA mismatch repair defect but does not define specific gene mutations responsible for cancers. If direct testing for gene mutations responsible for Lynch syndrome is desired, please call customer service at 800-345-4363 for more information. This assay can detect 8% to 12% of mutant in a background of wild-type genomic DNA. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
Microsatellite Instability570152Treating Physician18781-5
Microsatellite Instability570154Body Site39111-0

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 81301, 88381

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.