Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › JAK2V617F + CALR + MPL NGS Panel

JAK2V617F + CALR + MPL NGS Panel: Labcorp test 489615

Labcorp test 489615, CPT 81219, 81270, 81338. Specimen: Whole blood or bone marrow. Turnaround: 7 days.

JAK2V617F + CALR + MPL NGS Panel is Labcorp test code 489615, billed with CPT 81219, 81270, 81338. Specimen: Whole blood or bone marrow. Turnaround time: 7 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code489615
CPT81219; 81270; 81338
LOINC43399-5, 53761-3
SpecimenWhole blood or bone marrow
Volume3 to 5 mL whole blood or 1 to 2 mL bone marrow
Minimum volume3 mL whole blood or 1 mL bone marrow
ContainerLavender-top (EDTA) tube, green-top (sodium heparin) tube, yellow-top (ACD) tube, tan-top (K2-EDTA) tube or pink-top (K2-EDTA) tube
Turnaround time7 days
Storage / transportShip at room temperature. If specimen is to be stored prior to shipment, store at 2°C to 8°C.

Use

Molecular testing of blood or bone marrow is useful in the evaluation of suspected myeloproliferative neoplasms (MPN). Mutations in the JAK2, MPL and CALR genes are present in virtually all MPNs and their presence help distinguish benign reactive processes from clonal neoplasms. These mutations are generally considered mutually exclusive, although concurrent clones have been reported in rare patients. The JAK2 (Janus kinase 2) gene encodes for a non-receptor protein tyrosine kinase that activates cytokine and growth factor signaling. The V617F (c.1849 G>T) mutation results in constitutive activation of JAK2 and downstream STAT5 and ERK signaling. The V617F mutation is observed in…

Methodology

Amplicon-based Next Generation Sequencing

Collection instructions

Submit at room temperature. Specimens should arrive in the laboratory within 48 hours of collection. Indicate date and time of collection on test request form.

Causes for rejection

Specimen does not meet all of the criteria for sample type, container, minimum volume, collection and storage; frozen whole blood or marrow; leaking tube; clotted blood or marrow; grossly hemolyzed or otherwise visibly degraded; contamination by another specimen; specimen containing foreign material

Limitations

This assay has a sensitivity of approximately 1% VAF for JAK2 mutations and 2.5% VAF for CALR and MPL mutations. Deletions in CALR up to 70 bp and insertions up to 12 bp have been detected in validation studies. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
NGS JAK2 V617F/CALR/MPL489616JAK2 V617F Result43399-5
JAK2 V617F %%53761-3

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 81219, 81270, 81338

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation