MPL Mutation Detection by Capillary Electrophoresis: ARUP Laboratories test 2005545
ARUP Laboratories test 2005545, CPT 81338. Specimen: Whole blood or bone marrow in lavender (EDTA) or pink (K2EDTA).. Turnaround: 7-12 days.
Also known as: JAK-2 negative MPN diagnosis; JAK2 V617 negative testing; MPL 1p34
Use
May be useful when essential thrombocythemia or idiopathic myelofibrosis is suspected in JAK2 V617F-negative individuals.
Methodology
Capillary Electrophoresis
Collection instructions
Whole Blood: Do not freeze. Transport 5 mL whole blood. (Min: 1 mL) Bone Marrow: Transport 3 mL bone marrow. (Min: 1 mL)
Stability
Refrigerated: 7 days; Frozen: Unacceptable
Causes for rejection
Plasma, serum, FFPE tissue blocks/slides, or frozen tissue. Specimens collected in anticoagulants other than EDTA. Clotted or grossly hemolyzed specimens.
Performed
Varies
Compliance Category
Laboratory Developed Test (LDT)
New York DOH Approval Status
This test is New York state approved.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 2005546 | MPL Results | 62948-5 | |
| 3016757 | MPL, Source | 31208-2 |
View this test on ARUP Laboratories's website → · Last checked 2026-11-29
Other tests billed with CPT 81338
- JAK2 (V617F) Mutation by ddPCR, Qualitative With Reflex to CALR (Calreticulin) Exon 9 Mutation Analysis by PCR and MPL Mutation Detection
- JAK2 E12-15 + CALR + MPL NGS Panel
- JAK2V617F + CALR + MPL NGS Panel
- MPL Mutation
- MPL Mutation Analysis
- MPL 515 Mutation Analysis
Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.