Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › JAK2 V617F Mutation Analysis, Quantitative

JAK2 V617F Mutation Analysis, Quantitative: Labcorp test 481020

Labcorp test 481020, CPT 81270. Specimen: Whole blood, bone marrow or cell pellet. Turnaround: 5 - 7 days.

JAK2 V617F Mutation Analysis, Quantitative is Labcorp test code 481020, billed with CPT 81270. Specimen: Whole blood, bone marrow or cell pellet. Turnaround time: 5 - 7 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code481020
CPT81270
LOINC49549-9, 53761-3, 72486-4
SpecimenWhole blood, bone marrow or cell pellet
Volume3 to 5 mL whole blood or 1 to 2 mL bone marrow
Minimum volume3 mL whole blood or 1 mL bone marrow
ContainerLavender-top (EDTA) tube, green-top (sodium heparin) tube, tan-top (K2-EDTA) tube or pink-top (K2-EDTA) tube
Turnaround time5 - 7 days
Storage / transportShip at room temperature. If specimen is to be stored prior to shipment, store at 2°C to 8°C.

Use

The quantitative real-time PCR assay detects V617F mutation (c.1849 G>T) observed in approximately 95% polycythemia vera (pv), 55% essential thrombocythemia (ET), and 55% primary myelofibrosis (PMF). It is also infrequently present (3% to 5%) in myelodysplastic syndrome, chronic myelomonocytic leukemia, and other atypical chronic myeloid disorders. The results should be interpreted in the context of all clinical and laboratory findings. No therapeutic action should be taken based solely on these results.

Methodology

Total genomic DNA was extracted and subjected to TaqMan® real-time PCR amplification/detection. Two amplification products per sample were monitored by real-time PCR using primers/probes specific to JAK2 wild type (WT) and JAK2 mutant V617F. The ABI7900 Absolute Quantitation software will compare the patient specimen values to the standard curves and generate percent values for wild type and mutant type. The numerical values of sample Mutant Quantity/(Sample Mutant Quantity + Sample Wild Type Quantity) X100 is reported as a percentage.

Collection instructions

Submit at room temperature. Specimen should arrive at the testing laboratory within 48 hours of collection. Indicate the date and time of collection on the test request form.

Causes for rejection

Specimen does not meet collection criteria; frozen whole blood, marrow, or cell pellet; leaking tube; clotted blood or marrow; grossly hemolyzed specimen or otherwise visibly degraded; contamination by another specimen; specimens containing suspicious foreign material.

Special instructions

Please provide indications for JAK2 testing and specimen type. Direct any questions regarding this test to customer service at 800-345-4363.

Limitations

This assay detects only the JAK2 point mutation. Other mutations that may occur in the JAK2 gene will not be detected. In vitro studies have indicated that this assay has an analytical sensitivity of 1%. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
481026Quantitative Value:%53761-3
JAK2 V617F, Quantitative480999Methodology:49549-9
JAK2 V617F, Quantitative481132Director Review:72486-4

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 81270

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.