JAK2V617F Digital: Labcorp test 489477

Labcorp test 489477, CPT 81270. Specimen: Blood or bone marrow, cell pellet. Turnaround: 5 - 7 days.

JAK2V617F Digital is Labcorp test code 489477, billed with CPT 81270. Specimen: Blood or bone marrow, cell pellet. Turnaround time: 5 - 7 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code489477
CPT81270
LOINC43399-5, 49549-9, 53761-3, 62364-5, 66746-9
SpecimenBlood or bone marrow, cell pellet
Volume3 to 5 mL whole blood or 1 to 2 mL bone marrow
Minimum volume3 mL whole blood or 1 mL bone marrow
ContainerGreen-top (heparin) tube, lavender-top (EDTA) tube
Turnaround time5 - 7 days
Storage / transportShip at room temperature. If specimen is to be stored prior to shipment, store at 2°C to 8°C.

Use

The JAK2 (Janus kinase 2) gene encodes for a non-receptor protein tyrosine kinase that activates cytokine and growth factor signaling. The V617F (c.1849 G>T) mutation results in constitutive activation of JAK2 and downstream STAT5 and ERK signaling. The V617F mutation is observed in approximately 95% of polycythemia vera (PV), 60% of essential thrombocythemia (ET) and primary myelofibrosis (PMF). It is also infrequently present (3% to 5%) in myelodysplastic syndrome, chronic myelomonocytic leukemia and other atypical chronic myeloid disorders. JAK2 mutation allele burden correlates with clinical phenotype, with low levels of mutant allele characterized by thrombocytosis, intermediate levels…

Methodology

Nanoplate Digital PCR (dPCR); total genomic DNA is extracted and amplified using a multiplex digital PCR using wild-type and mutant-specific probes. The assay is designed to detect JAK2 (c. 1849G>T, p.V617F) mutation. Results are reported as percent-mutated alleles.

Collection instructions

Submit at room temperature. Specimen should arrive at the testing laboratory within 48 hours of collection. Indicate the date and time of collection on test request form.

Causes for rejection

Specimen does not meet all of the above criteria for sample type, container, minimum volume, collection and storage (unsuitable specimens include but are not limited to: frozen whole blood or marrow; a leaking tube; clotted blood or marrow; a grossly hemolyzed specimen or otherwise visibly degraded); specimen is suspected of being contaminated by another specimen; specimens containing suspicious foreign material

Special instructions

Please direct any questions regarding this test to customer service at 800-345-4363.

Limitations

This assay has a sensitivity of approximately 0.15% VAF for JAK2 . This test will detect the JAK2 mutation only. A negative result does not exclude the possibility that other mutations in JAK2 are present, or that the JAK2 mutation is present below the test limit of detection. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration. The results should be interpreted in the context of all clinical and laboratory findings. No therapeutic action should be taken based solely on these results.

LOINC map

Result codeResult nameUnitsResult LOINC
489478Result43399-5
489479Quantitative Value%53761-3
489480Specimen Type66746-9
489481Background62364-5
489482Method/Limitations49549-9

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 81270

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation