Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › JAK2 E12-15 + CALR + MPL NGS Panel

JAK2 E12-15 + CALR + MPL NGS Panel: Labcorp test 489514

Labcorp test 489514, CPT 81219, 81279, 81338. Specimen: Whole blood or bone marrow. Turnaround: 7 days.

JAK2 E12-15 + CALR + MPL NGS Panel is Labcorp test code 489514, billed with CPT 81219, 81279, 81338. Specimen: Whole blood or bone marrow. Turnaround time: 7 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code489514
CPT81219; 81279; 81338
LOINC48004-6, 48726-4
SpecimenWhole blood or bone marrow
Volume3 to 5 mL whole blood or 1 to 2 mL bone marrow
Minimum volume3 mL whole blood or 1 mL bone marrow
ContainerLavender-top (EDTA) tube, green-top (sodium heparin) tube, yellow-top (ACD) tube, tan-top (K2-EDTA) tube or pink-top (K2-EDTA) tube
Turnaround time7 days
Storage / transportShip at room temperature. If specimen is to be stored prior to shipment, store at 2°C to 8°C.

Use

The JAK2 (Janus kinase 2) gene encodes for a non-receptor protein tyrosine kinase that activates cytokine and growth factor signaling. The V617F (c.1849 G>T) mutation results in constitutive activation of JAK2 and downstream STAT5 and ERK signaling. The V617F mutation is observed in approximately 95% of polycythemia vera (PV), 60% of essential thrombocythemia (ET) and primary myelofibrosis (PMF). It is also infrequently present (3-5%) in myelodysplastic syndrome, chronic myelomonocytic leukemia and other atypical chronic myeloid disorders. A small percentage of JAK2 mutation-positive patients (3.3%) contain other non-V617F mutations within exons 12 to 15. In particular, mutations in exon 12…

Methodology

Amplicon-based Next Generation Sequencing

Collection instructions

Submit at room temperature. Specimens should arrive in the laboratory within 48 hours of collection. Indicate date and time of collection on test request form.

Causes for rejection

Specimen does not meet all of the criteria for sample type, container, minimum volume, collection and storage; frozen whole blood or marrow; leaking tube; clotted blood or marrow; grossly hemolyzed or otherwise visibly degraded; contamination by another specimen; specimen containing foreign material

Limitations

This assay has a sensitivity of approximately 1% VAF for JAK2 and 2.5% VAF for other mutations in JAK2 exons 12 to 15, CALR mutations and MPL mutations. Deletions in JAK2 up to 6 bp and insertions up to 34 bp have been detected in validation studies. Deletions in CALR up to 70 bp and insertions up to 12 bp have been detected in validation studies. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
NGS JAK2 E12-15/CALR/MPL489523E12-15 Result48726-4
NGS JAK2 E12-15/CALR/MPL489525E12-15 Nucleotide48004-6

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 81219, 81279, 81338

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.