Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › JAK2 Exon 12 Mutation

JAK2 Exon 12 Mutation: Michigan Medicine Laboratories (MLabs) test EX12

Michigan Medicine Laboratories (MLabs) test EX12, CPT 81279. Specimen: 5 mL EDTA (lavender) whole blood; 3 mL EDTA (lavender) bone marrow; Fresh/frozen cells in RPMI. Extracted DNA is also ac. Turnaround: 2 - 7 days.

JAK2 Exon 12 Mutation is Michigan Medicine Laboratories (MLabs) test code EX12, billed with CPT 81279. Specimen: 5 mL EDTA (lavender) whole blood; 3 mL EDTA (lavender) bone marrow; Fresh/frozen cells in RPMI. Extracted DNA is also acceptable if extracte. Turnaround time: 2 - 7 days. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Labcorp.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeEX12
CPT81279
LOINC—
Specimen5 mL EDTA (lavender) whole blood; 3 mL EDTA (lavender) bone marrow; Fresh/frozen cells in RPMI. Extracted DNA is also acceptable if extracted in a CLIA certified laboratory.
Volume5 mL EDTA (lavender) whole blood; 3 mL EDTA (lavender) bone marrow; Fresh/frozen cells in RPMI. Extracted DNA is also acceptable if extracted in a CLIA certified laboratory.
Turnaround time2 - 7 days

Also known as: Polycythemia Vera

Use

Mutations within exon 12 of the JAK2 gene occur in most cases of JAK2 V617F-mutation negative polycythemia vera. Testing for JAK2 exon 12 mutations may aid in the diagnosis of polycythemia vera, and is recommended in patients with JAK2 V617F-negative erythrocytosis. This test will qualitatively detect JAK2 exon 12 mutations in peripheral blood or bone marrow specimens. This is a second order test and should be used only following a JAK2 V617F-negative result.

Collection instructions

Collect blood or bone marrow in a lavender top tube. Refrigerate and send intact blood or bone marrow specimen within 48 hours of collection. Fresh cell suspensions in RPMI should be refrigerated and sent, preferably within 48 hours. Frozen cell suspensions – preferably frozen with 1 hour of collection – may also be sent frozen on dry ice.

Reference range

Interpretive report provided.

Limitations

The limit of detection of this assay is 1% mutant allele. Mutations may not be detected in samples with a neoplastic burden below this level. In addition, this test will only detect insertions, deletions or K539L. Rare substitution mutations other than K539L (accounting for less than 5% of described JAK2 exon 12 mutations) will not be detected.

Section

Molecular Diagnostics

Performed

Monday - Thursday

Contraindications

This test is not indicated for inpatient evaluation of acute thrombosis.

NY State approved

No

Alternate specimens

The preferred specimen is whole blood or bone marrow collected in EDTA (lavender top). However, ACD (yellow top) and heparin (green top) may also be accepted. Previously extracted DNA may also be accepted.

Performing Laboratory

Molecular Diagnostics

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 81279

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation