JAK2 Exon 12 Mutation: Michigan Medicine Laboratories (MLabs) test EX12
Michigan Medicine Laboratories (MLabs) test EX12, CPT 81279. Specimen: 5 mL EDTA (lavender) whole blood; 3 mL EDTA (lavender) bone marrow; Fresh/frozen cells in RPMI. Extracted DNA is also ac. Turnaround: 2 - 7 days.
Also known as: Polycythemia Vera
Use
Mutations within exon 12 of the JAK2 gene occur in most cases of JAK2 V617F-mutation negative polycythemia vera. Testing for JAK2 exon 12 mutations may aid in the diagnosis of polycythemia vera, and is recommended in patients with JAK2 V617F-negative erythrocytosis. This test will qualitatively detect JAK2 exon 12 mutations in peripheral blood or bone marrow specimens. This is a second order test and should be used only following a JAK2 V617F-negative result.
Collection instructions
Collect blood or bone marrow in a lavender top tube. Refrigerate and send intact blood or bone marrow specimen within 48 hours of collection. Fresh cell suspensions in RPMI should be refrigerated and sent, preferably within 48 hours. Frozen cell suspensions – preferably frozen with 1 hour of collection – may also be sent frozen on dry ice.
Reference range
Interpretive report provided.
Limitations
The limit of detection of this assay is 1% mutant allele. Mutations may not be detected in samples with a neoplastic burden below this level. In addition, this test will only detect insertions, deletions or K539L. Rare substitution mutations other than K539L (accounting for less than 5% of described JAK2 exon 12 mutations) will not be detected.
Section
Molecular Diagnostics
Performed
Monday - Thursday
Contraindications
This test is not indicated for inpatient evaluation of acute thrombosis.
NY State approved
No
Alternate specimens
The preferred specimen is whole blood or bone marrow collected in EDTA (lavender top). However, ACD (yellow top) and heparin (green top) may also be accepted. Previously extracted DNA may also be accepted.
Performing Laboratory
Molecular Diagnostics
View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29
Other tests billed with CPT 81279
- JAK2 (V617F) Mutation by ddPCR, Qualitative With Reflex to JAK2 Exon 12-Mutation Analysis by PCR
- JAK2 E12-15 + CALR + MPL NGS Panel
- JAK2 Exon 12-Mutation Analysis by PCR
- JAK2 Exon 12, 13, 14 and 15 Mutation Analysis
- JAK2 Exon 12, 13, 14 and 15 Mutation Analysis by NGS
Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation