Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › JAK2 Exon 12, 13, 14 and 15 Mutation Analysis

JAK2 Exon 12, 13, 14 and 15 Mutation Analysis: Labcorp test 115101

Labcorp test 115101, CPT 81279. Specimen: Whole blood or bone marrow. Turnaround: 6 - 9 days.

JAK2 Exon 12, 13, 14 and 15 Mutation Analysis is Labcorp test code 115101, billed with CPT 81279. Specimen: Whole blood or bone marrow. Turnaround time: 6 - 9 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code115101
CPT81279
LOINC—
SpecimenWhole blood or bone marrow
Volume3 to 5 mL whole blood or 1 to 2 mL bone marrow
Minimum volume3 mL whole blood or 1 mL bone marrow
ContainerLavender-top (EDTA) tube, green-top (sodium heparin) tube or yellow-top (ACD) tube
Turnaround time6 - 9 days
Storage / transportRefrigerate

Use

The JAK2 (exon 14) mutation analysis can be used in conjunction with bone marrow histology and cytogenetic analysis to assist in the diagnosis of myeloproliferative neoplasma (MPN). The JAK2 mutation is found in almost all patients with polycythemia vera (PV) and in nearly one-half of those with idiopathic myelofibrosis (IMF) and with essential thrombocythemia (ET). A small percentage (~3.3%) of JAK2 mutation positive patient contain other non- V617F mutations within exons 12 to 15.

Methodology

Reverse transcription polymerase chain reaction RT-PCR and Sanger sequencing

Collection instructions

At room temperature (18-26°C)

Causes for rejection

Specimen does not meet all of the criteria for sample type, container, minimum volume, collection and storage; frozen whole blood or marrow; leaking tube; clotted blood or marrow; grossly hemolyzed or otherwise visibly degraded; contamination by another specimen; specimen containing foreign material

Limitations

In vitro studies indicate that this analysis has a mutation detection sensitivity of 15%. Mutations occurring outside of the analyzed region of the JAK2 gene will not be detected by this assay. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

Disease

Hematologic malignancies Myeloproliferative neoplasm (MPN)

Technology

Molecular

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 81279

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation