Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › POLE Mutation NGS, Tumor

POLE Mutation NGS, Tumor: Labcorp test 452571

Labcorp test 452571, CPT 81402, 88381. Specimen: Formalin fixed paraffin-embedded (FFPE) tissue.

POLE Mutation NGS, Tumor is Labcorp test code 452571, billed with CPT 81402, 88381. Specimen: Formalin fixed paraffin-embedded (FFPE) tissue. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC).
LaboratoryLabcorp
CLIA number34D0655059
Test code452571
CPT81402; 88381
LOINC105597-9, 42349-1, 48005-3, 48019-4, 82771-7
SpecimenFormalin fixed paraffin-embedded (FFPE) tissue
VolumeTen unstained slides at 5 µM and one matching H&E slide
Minimum volume50mm total tumor area is required for testing.
ContainerParaffin block; slide
Storage / transportStore FFPE specimens at room temperature.

Use

This assay is designed to detect mutations in exons 8-14 of the POLE gene, encompassing the POLE exonuclease domain. Somatic mutations in the POLE exonuclease domain are associated with a hypermutator phenotype and used in the molecular classification of some cancers. Specific mutations in the POLE exonuclease domain have been associated with a hypermutator state, exhibiting a mutation rate one order of magnitude higher than mismatch repair (MMR) deficient tumors, at a rate of >100 mutations per mb. For the hypermutator phenotype, the functionality of POLE synthesis must be maintained with only the exonuclease proofreading capabilities impacted. Amino acid changes and subsequent genomic…

Methodology

Amplicon-based next-generation sequencing

Collection instructions

Formalin-fixed, paraffin-embedded (FFPE) tissue block or slides

Limitations

This assay has an analytical sensitivity of approximately 2% Variant Allele Frequency (VAF). A negative result does not exclude the possibility that other mutations in POLE are present outside of the targeted regions or that mutations are present below the assay limit of detection. This test cannot differentiate between somatic mutations and germline alterations. Additional testing may be necessary to clarify the significance of results if there is a potential hereditary risk. The results should be interpreted in the context of all clinical and laboratory findings. No therapeutic action should be taken based solely on these results. This test was developed and its performance…

Disease

Endometrial

Technology

NGS

LOINC map

Result codeResult nameUnitsResult LOINC
452572POLE Result105597-9
452573POLE Nuc Change48019-4
452574POLE Amino Acid Change48005-3
452575Indication42349-1
452576Location82771-7

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 81402, 88381

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation