Labcorp test 452514, CPT 81455, 88381. Specimen: Formalin-fixed, paraffin-embedded (FFPE) tissue block or slides. Turnaround: 14 - 21 days.

Labcorp Pan-Heme NGS (FFPE) is Labcorp test code 452514, billed with CPT 81455, 88381. Specimen: Formalin-fixed, paraffin-embedded (FFPE) tissue block or slides. Turnaround time: 14 - 21 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code452514 (Onc)
CPT81455; 88381
LOINC31208-2, 42349-1, 66746-9
SpecimenFormalin-fixed, paraffin-embedded (FFPE) tissue block or slides
VolumeTen unstained slides at 5 µM and one matching H&E slide or formalin-fixed, paraffin-embedded tissue block
Minimum volume50mm total tumor area is required for testing; two unstained slides at 5 μM and one matching H&E slide or three unstained slides at 5 μM
ContainerFFPE tissue block or slides
Turnaround time14 - 21 days
Storage / transportStore FFPE specimens at room temperature.

Test includes

This test includes the following genes: ABL1, ANKRD26, ARID1A, ASXL1, ATM, ATRX, B2M, BCL2, BCL6, BCOR, BCORL1, BIRC3, BRAF, BRCC3, BTK, CALR, CARD11, CBL, CBLB, CBLC, CCND1, CCND3, CD274, CD79A, CD79B, CDK4, CDKN1B, CDKN2A, CDKN2B, CEBPA, CIITA, CREBBP, CRLF2, CSF1R, CSF3R, CSNK1A1, CTCF, CUX1, CXCR4, DDX41, DKC1, DNMT3A, EBF1, ELANE, EP300, ERG, ETNK1, ETV6, EZH2, FAS, FBXW7, FGFR1, FGFR3, FLT3, FOXO1, GATA1, GATA2, GNA13, GNAS, GNB1, HRAS, IDH1, IDH2, IKZF1, IKZF3, IL7R, IRF4, JAK1, JAK2, JAK3, KDM6A, KIT, KMT2A, KRAS, MALT1, MAP2K1, MAPK1, MED12, MEF2B, MPL, MYC, MYD88, NF1, NFE2, NOTCH1, NOTCH2, NPM1, NRAS, NSD2, NT5C2, P2RY8, PAX5, PDCD1, PDGFRA, PHF6, PIGA, PIK3CA, PIK3CD, PIK3CG, PIK3R1, PIM1, PLCG2, PML, POT1, PPM1D, PRDM1, PRPF8, PTEN, PTPN11, RAD21, RB1, RHOA, RIT1, RUNX1, SAMD9, SAMD9L, SBDS, SETBP1, SETD2, SF3B1, SH2B3, SMC1A, SMC3, SOCS1, SRSF2, STAG2, STAT3, STAT5B, STAT6, TCF3, TERC, TERT, TET2, TNFAIP3, TNFRSF14, TP53, U2AF1, WT1, UBA1, XPO1 and ZRSR2.

Use

This test is used to aid diagnosis, prognostic risk assessment and therapeutic selection in hematologic malignancies.

Methodology

The Labcorp Pan-Heme FFPE NGS assay utilizes capture-based next-generation sequencing of whole genomic DNA libraries to identify gene alterations that have diagnostic, prognostic and therapeutic significance in hematologic malignancies. Somatic mutations in the genes analyzed include single nucleotide variants (SNVs) as well as insertions and deletions (indels) in 141 genes.

Causes for rejection

Specimen does not meet criteria for sample type, container, minimum volume, collection and storage; contaminated specimen; contains suspicious foreign material

Special instructions

Please provide a clinical indication or related ICD-10 code on the requisition. Test will be delayed if the clinical indication is not received. Please direct any questions regarding this test to customer service at 800-345-4363.

Limitations

The analytical sensitivity of this assay is 5% Variant Allele (VAF) for Single Nucleotide Variants (SNV), 5% for insertions/deletions (indels) <25 base pairs (bp) and 15% for indels ≥25 bp. The clinically actionable FLT3-ITD hotspot has increased VAF sensitivity down to 5% regardless of size. Insertions and deletions of up to 50 bp are detected when at least one breakpoint is contained within a sequence read. Insertions up to 34 bp and deletions up to 33 bp have been detected in clinical specimens. Mutations outside the targeted regions and gene rearrangements will not be detected. Variants are categorized into tiers based on their clinical impact, following a joint consensus recommendation…

Disease

Hematologic malignancies

LOINC map

Result codeResult nameUnitsResult LOINC
Pan-Heme FFPE (NGS)452516Specimen Type31208-2
Pan-Heme FFPE (NGS)452518Indication42349-1
Pan-Heme FFPE (NGS)452543Body Site66746-9

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 81455, 88381

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation