Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Lupus Anticoagulant With Reflex

Lupus Anticoagulant With Reflex (Women's Health): Labcorp test 117892

Labcorp test 117892, CPT 85613, 85732. Specimen: Plasma, frozen. Turnaround: 2 - 3 days.

Lupus Anticoagulant With Reflex is Labcorp test code 117892, billed with CPT 85613, 85732. Specimen: Plasma, frozen. Turnaround time: 2 - 3 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code117892 (Women's Health)
CPT85613; 85732. If reflex testing is performed, concomitant CPT codes/charges will apply.
LOINC34571-0, 6303-2, 75514-0, 75515-7
SpecimenPlasma, frozen
Volume2 mL
Minimum volume1 mL ( Note: This volume does not allow for repeat testing.)
ContainerBlue-top (sodium citrate) tube
Turnaround time2 - 3 days
Storage / transportFreeze.

Also known as: Lupus Anticoagulant; Lupus Anticoagulant Screen

Use

This test is used for qualitative detection of lupus anticoagulants in plasma.

Methodology

PTT-LA (lupus-sensitive aPTT) and dRVVT screen; mixing study if screening tests are prolonged; confirmation if the mixing studies do not correct

Collection instructions

Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples unless the sample is collected using a winged (butterfly) collection system. With a winged blood collection set a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube. When non-citrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove / 3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap, and re-centrifuge for 10 minutes. Use a second plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.

Stability

TemperaturePeriod
Frozen28 days
Freeze/thaw cyclesStable x3

Patient preparation

Ideally, the patient should not be on anticoagulant therapy. Avoid warfarin (Coumadin®) therapy for two weeks prior to the test and heparin, direct Xa, and thrombin inhibitor therapies for about three days prior to testing.

Causes for rejection

Severe hemolysis; improper labeling; clotted specimen; specimen diluted with IV fluids; samples thawed in transit; improper sample type; sample out of stability

Limitations

Patients with high clinical suspicion of having APS, but without presence of criteria aPL, are suggested to have “seronegative APS” (SNAPS). These patients may be positive for so-called non-criteria aPL or be negative for the criteria aPL through insufficient sensitivity of the assays. Inherent to the test principle of phospholipid-based coagulation assays, LAC testing is prone to interferences. Elevated c-reactive protein interferes in vitro with aPTT testing through its affinity for phospholipids, leading to false-positive results of the LAC test. Increased factor VIII (FVIII) coagulant activity is associated with shorter aPTT clotting times and can lead to false-negative LAC aPTT…

LOINC map

Result codeResult nameUnitsResult LOINC
117003PTT-LAsec34571-0
117891dRVVTsec6303-2
117893Lupus Reflex Interpretation75514-0

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 85613, 85732

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation