ADAMTS13 Activity Reflex Profile: Labcorp test 117921
Labcorp test 117921, CPT 85397. Specimen: Plasma, frozen. Turnaround: 2 - 4 days.
Test includes
This test includes ADAMTS13 activity with reflex to ADAMTS13 antibody when activity is less than 30%.
Use
This test is used for differentiating thrombotic thrombocytopenic purpura (TTP) from a number of clinically similar conditions. The reflex to antibody assay is used to differentiate congenital from autoimmune ADAMTS13 deficiency.
Methodology
In Labcorp’s liquid chromatography‐tandem mass spectrometry (LC/MS-MS) assay, ADAMTS13 activity is determined by measuring the cleavage of a synthetic polypeptide substrate (referred to as vWF73) added to plasma samples. The amino acid sequence of vWF73 corresponds to amino acid residues 1596 through 1668 of mature von Willebrand Factor (vWF) and, thereby, possesses the tyrosine‐methionine cleavage site and exosite necessary to undergo specific cleavage by plasma ADAMTS13. Using LC/MS-MS, cleavage of vWF73 is determined directly by measuring a specific proteolytic product of vWF73 whose quantity is directly proportional to the activity of ADAMTS13 in plasma. The LC/MS-MS activity assay is…
Collection instructions
Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tubes. Serum gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and (using a transfer pipette) carefully remove two-thirds of the plasma without disturbing the cells. Deliver to a plastic transport tube, cap, and recentrifuge for 10 minutes. Use a second plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). The specimen should be frozen immediately and maintained frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested.
Stability
| Temperature | Period |
|---|---|
| Room temperature | 2 hours |
| Frozen | 14 days |
| Freeze/thaw cycles | Stable x3 |
Causes for rejection
Severe hemolysis; improper labeling; clotted specimen; specimen diluted with IV fluids; receipt of non-frozen sample; receipt of non-separated sample; receipt of EDTA plasma; receipt of serum; sample out of stability
Limitations
This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 117928 | ADAMTS13 Activity | % | 53622-7 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 85397
- ADAMTS13 Activity
- ADAMTS13 Activity
- ADAMTS13 Activity Assay
- ADAMTS13 Evaluation
- ADAMTS13 Reflex Panel
- COVID-19 Induced Thrombotic Microangiopathy Profile
- Prolonged Clot Time Reflexive Profile
- von Willebrand Factor (VWF) GPIbM Activity
- von Willebrand Factor Multimeric Panel
- von Willebrand Factor Panel
- von Willebrand Factor Panel With Reflex to von Willebrand Multimers
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.