Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › ADAMTS13 Activity

ADAMTS13 Activity: Labcorp test 117913

Labcorp test 117913, CPT 85397. Specimen: Plasma, frozen. Turnaround: 1 - 2 days.

ADAMTS13 Activity is Labcorp test code 117913, billed with CPT 85397. Specimen: Plasma, frozen. Turnaround time: 1 - 2 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code117913
CPT85397
LOINC53622-7
SpecimenPlasma, frozen
Volume0.5 mL
Minimum volume0.3 mL ( Note: This volume does not allow for repeat testing.)
ContainerBlue-top (sodium citrate) tube
Turnaround time1 - 2 days
Storage / transportFreeze.

Also known as: von Willebrand Factor-cleaving Protease

Use

This test is used for differentiating thrombotic thrombocytopenic purpura (TTP) from a number of clinically similar conditions.

Methodology

In Labcorp’s liquid chromatography‐tandem mass spectrometry (LC/MS-MS) assay, ADAMTS13 activity is determined by measuring the cleavage of a synthetic polypeptide substrate (referred to as vWF73) added to plasma samples. The amino acid sequence of vWF73 corresponds to amino acid residues 1596 through 1668 of mature von Willebrand Factor (vWF) and, thereby, possesses the tyrosine‐methionine cleavage site and exosite necessary to undergo specific cleavage by plasma ADAMTS13. Using LC/MS-MS, cleavage of vWF73 is determined directly by measuring a specific proteolytic product of vWF73 whose quantity is directly proportional to the activity of ADAMTS13 in plasma. The LC/MS-MS activity assay is…

Collection instructions

Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Serum gel-barrier tubes and serum tubes with clot initiators should aslo be collected after the citrate tubes. Centrifuge and carefully remove the plasma using a plastic transfer pipette, being careful not to disturb the cells. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). The specimen should be frozen immediately and maintained frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested . Please see Shipping Procedure for Priority ADAMTS13 Activity for information on direct shipping procedures.

Stability

TemperaturePeriod
Room temperature2 hours
Frozen14 days
Freeze/thaw cyclesStable x3

Causes for rejection

Severe hemolysis; improper labeling; clotted specimen; specimen diluted with IV fluids; receipt of non-frozen sample; receipt of non-separated sample; receipt of EDTA plasma; receipt of serum; sample out of stability

Limitations

This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
117928ADAMTS13 Activity%53622-7

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 85397

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation