Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Cortisol, LC/MS, Saliva, 3 Samples

Cortisol, LC/MS, Saliva, 3 Samples: Quest Diagnostics test 92687

Quest Diagnostics test 92687, CPT 82533. Specimen: 0.5 mL saliva collected in each of three separate Salivette® Cortisol with blue screw-cap.

Cortisol, LC/MS, Saliva, 3 Samples is Quest Diagnostics test code 92687, billed with CPT 82533. Specimen: 0.5 mL saliva collected in each of three separate Salivette® Cortisol with blue screw-cap. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), ARUP Laboratories, Labcorp, Cleveland Clinic Laboratories, OHSU Laboratory Services.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code92687
CPT82533 (x3)
LOINC—
Specimen0.5 mL saliva collected in each of three separate Salivette® Cortisol with blue screw-cap
Minimum volume0.2 mL (x3)
ContainerSuper SAL™ Universal Saliva Collection Kits
Storage / transportRefrigerated (cold packs)

Also known as: Compound F; Hydroxycortisone

Methodology

Chromatography/Mass Spectrometry

Collection instructions

a. Saliva collection should be done at the earliest 60 minutes after brushing teeth, a meal (liquid/solid food intake) or oral intake of medication and 10 minutes after rinsing the mouth with water in order to avoid contamination of the saliva by interfering substances. b. Remove the swab from the Salivette. c. Place the swab in the mouth, e.g. in your cheek, where it should remain for 2 minutes without chewing. If an extremely small amount of saliva is produced, leave the swab in the mouth for longer. d. Return the swab with the absorbed saliva to the Salivette. e. Replace the stopper. f. Refrigerate the Salivette immediately.

Stability

TemperaturePeriod
Room temperature72 hours
Refrigerated21 days
Frozen6 months

Causes for rejection

Hemolysis • White-top Salivette collection devices

Reference range

See Laboratory Report

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Alternative specimen(s)

Super SAL™ or Super SAL2™ Universal Saliva Kit

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 82533

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation