Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Cortisol Response to ACTH Stimulation, Serum

Cortisol Response to ACTH Stimulation, Serum: Quest Diagnostics test 38149

Quest Diagnostics test 38149, CPT 82533. Specimen: 1 mL serum collected in each of four separate red top tubes (no gel).

Cortisol Response to ACTH Stimulation, Serum is Quest Diagnostics test code 38149, billed with CPT 82533. Specimen: 1 mL serum collected in each of four separate red top tubes (no gel). Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), ARUP Laboratories, Labcorp, Cleveland Clinic Laboratories, OHSU Laboratory Services.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code38149
CPT82533 (x4)
LOINC—
Specimen1 mL serum collected in each of four separate red top tubes (no gel)
Minimum volume0.2 mL for each timed specimen
ContainerTransport tube(s)
Storage / transportRoom temperature

Methodology

Chromatography/Mass Spectrometry

Collection instructions

Draw morning baseline specimen. Administer 250 mcg Cortrosyn. Draw additional specimens at 15, 30 and 60 minutes. For each timed specimen submitted, each tube must be clearly marked with time drawn. Submit all tubes with one test request form. Note: Cortrosyn (cosyntropin) not supplied by the laboratory. This test cannot be collected at a Patient Service Center.

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated21 days
Frozen1 year

Causes for rejection

Gross hemolysis • Serum separator tubes (SST)

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Alternative specimen(s)

Plasma collected in: EDTA (lavender-top) tube

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 82533

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation