CAH Panel 4 (17-Hydroxylase Deficiency in Females): Quest Diagnostics test 15274
Quest Diagnostics test 15274, CPT 82088, 82528, 82533, 82670, 83498, 84144. Specimen: 3 mL serum collected in a red-top tube (no gel).
CAH Panel 4 (17-Hydroxylase Deficiency in Females) is Quest Diagnostics test code 15274, billed with CPT 82088, 82528, 82533, 82670, 83498, 84144. Specimen: 3 mL serum collected in a red-top tube (no gel). Performing laboratory: Quest Diagnostics, CLIA
49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories, Labcorp, Michigan Medicine Laboratories (MLabs).
Test code15274
CPT84144, 83498, 82528, 82533, 82088, 82670
LOINC—
Specimen3 mL serum collected in a red-top tube (no gel)
Minimum volume1.2 mL
ContainerTransport tube
Storage / transportRefrigerated (cold packs)
Methodology
Extraction • Immunoassay (IA) • Chromatography/Mass Spectrometry
Collection instructions
Specify time of day specimen was collected, patient age and sex on test request form
Stability
| Temperature | Period |
|---|
| Room temperature | 24 hours |
| Refrigerated | 7 days |
| Frozen | 28 days |
Patient preparation
An early morning specimen is preferred
Causes for rejection
Moderate to gross hemolysis • Received room temperature • Serum separator tubes (SST) • Grossly icteric • Glass tubes
Reference range
See Laboratory Report
Assay category
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.
View this test on Quest Diagnostics's website → · Last checked 2026-11-29
Other tests billed with CPT 82088, 82528, 82533
- Aldosterone
Cleveland Clinic LaboratoriesTest code ALDOCPT 82088SerumTAT 2 - 6 days
- Aldosterone 24 hr, Urine
Cleveland Clinic LaboratoriesTest code UALDO1CPT 82088Urine, 24-hour (well-mixed)TAT 3 - 7 days
- Aldosterone 30 Minute
ARUP LaboratoriesTest code 0070016CPT 82088Serum separator tube (SST) or plain red.TAT Within 24 hours
- Aldosterone 60 Minute
ARUP LaboratoriesTest code 0070017CPT 82088Serum separator tube (SST) or plain redTAT Within 24 hours
- Aldosterone Inferior Vena Cava
ARUP LaboratoriesTest code 3000484CPT 82088Adrenal venous sampling procedure is required. Serum Separator Tube (SST) or PlaTAT Within 24 hours
- Aldosterone Left Adrenal Vein
ARUP LaboratoriesTest code 3000485CPT 82088Adrenal venous sampling procedure is required. Serum Separator Tube (SST) or PlaTAT Within 24 hours
- Aldosterone Right Adrenal Vein
ARUP LaboratoriesTest code 3000486CPT 82088Serum Separator Tube (SST) or Plain Red.TAT Within 24 hours
- Aldosterone with Na and K, 24hr Urine
Cleveland Clinic LaboratoriesTest code UALDOSCPT 82088, 84133, 84300Urine, 24-hour (well-mixed)TAT 3 - 7 days
- Aldosterone, 24-Hour Urine
LabcorpTest code 004291CPT 82088Urine (24-hour)TAT 4 - 9 days
- Aldosterone, 24-Hour Urine
Quest DiagnosticsTest code 229CPT 82088, 825705 mL 24-hour urine collected in a 24-hour urine container
- Aldosterone, Adrenal Vein
Quest DiagnosticsTest code 95084CPT 820881 mL serum collected in a red-top tube (no gel)
- Aldosterone, LC/MS
LabcorpTest code 004374CPT 82088Serum or plasmaTAT 4 - 7 days
- Aldosterone, LC/MS (Endocrine Sciences)
LabcorpTest code 500467CPT 82088Serum or plasma, frozenTAT 5 - 10 days
- Aldosterone, LC/MS, Eight Specimens
LabcorpTest code 010848CPT 82088TAT 3 - 5 days
- Aldosterone, LC/MS, Five Specimens
LabcorpTest code 271190CPT 82088TAT 3 - 5 days
- Aldosterone, LC/MS, Four Specimens
LabcorpTest code 361626CPT 82088TAT 4 - 6 days
- Aldosterone, LC/MS, Seven Specimens
LabcorpTest code 015796CPT 82088TAT 3 - 5 days
- Aldosterone, LC/MS, Six Specimens
LabcorpTest code 015795CPT 82088TAT 3 - 5 days
- Aldosterone, LC/MS, Three Specimens
LabcorpTest code 053272CPT 82088TAT 4 - 6 days
- Aldosterone, LC/MS, Two Specimens
LabcorpTest code 237537CPT 82088TAT 4 - 6 days
- Aldosterone, LC/MS/MS
Quest DiagnosticsTest code 17181CPT 820881 mL serum collected in a red-top tube (no gel)
- Aldosterone, Serum
ARUP LaboratoriesTest code 0070015CPT 82088Serum separator tube (SST) or plain red.TAT Within 24 hours
- Aldosterone, Serum
Michigan Medicine Laboratories (MLabs)Test code SALDOCPT 820881 mL serumTAT 8 hours
- Aldosterone, Urine
ARUP LaboratoriesTest code 0070480CPT 8208824-hour urine. Urine must be refrigerated during collection.TAT 2-5 days
- Aldosterone, Urine
Michigan Medicine Laboratories (MLabs)Test code ALDUCPT 8208810 mL aliquot of 24 hour urine collectionTAT 2 - 7 days
- Aldosterone:Renin Ratio
LabcorpTest code 004354CPT 82088, 84244Serum (refrigerated) and plasma (frozen)TAT 4 - 7 days
- Aldosterone/Cortisol Ratio, Adrenal Vein Sampling, 1 Site
Quest DiagnosticsTest code 19573CPT 82088, 825332 mL serum collected in a red-top tube (no gel)
- Aldosterone/Direct Renin Ratio
Cleveland Clinic LaboratoriesTest code ALDRENCPT 82088, 84244PlasmaTAT 2 - 7 days
- Aldosterone/Plasma Renin Activity Ratio, LC/MS/MS
Quest DiagnosticsTest code 16845CPT 82088, 842441.8 mL frozen plasma collected in an EDTA (lavender-top) tube
- Aldosterone/Renin Activity Ratio
ARUP LaboratoriesTest code 0070073CPT 82088, 84244Serum separator tube (SST) AND lavender (K2EDTA) or pink (K2EDTA). Do not collecTAT 1-5 days
Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code.
Submit your lab's test menu → Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation