Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › CAH Panel 6 (StAR Deficiency)

CAH Panel 6 (StAR Deficiency): Quest Diagnostics test 15276

Quest Diagnostics test 15276, CPT 82088, 82533, 82626, 84140. Specimen: 4 mL serum collected in a red-top tube (no gel).

CAH Panel 6 (StAR Deficiency) is Quest Diagnostics test code 15276, billed with CPT 82088, 82533, 82626, 84140. Specimen: 4 mL serum collected in a red-top tube (no gel). Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories, Labcorp, Michigan Medicine Laboratories (MLabs).
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code15276
CPT82533, 84140, 82626, 82088
LOINC—
Specimen4 mL serum collected in a red-top tube (no gel)
Minimum volume1.6 mL
ContainerTransport tube Transport temperature Frozen

Also known as: Side chain cleavage deficiency

Methodology

Chromatography/Mass Spectrometry

Collection instructions

Collect blood in a Vacutainer® with no additives. Allow blood to clot (30 minutes) at room temperature, 18-25°C. Centrifuge and separate the serum from the cells. Freeze as soon as possible. Specify age and sex on test request form. Immediately put sample on ice after collection.

Stability

TemperaturePeriod
Room temperatureUnacceptable
Refrigerated72 hours
Frozen -20° C14 days
Frozen -70° C30 days

Patient preparation

Overnight fasting is preferred

Causes for rejection

Moderate to gross hemolysis • Serum separator tube (SST) • Plasma

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 82088, 82533, 82626

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation