Quest Diagnostics test 91716, CPT 80061. Specimen: 1 mL serum.
Lipid Panel, Cardio IQ® is Quest Diagnostics test code 91716, billed with CPT 80061. Specimen: 1 mL serum. Performing laboratory: Quest Diagnostics, CLIA
49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Labcorp, Allina Health Laboratory (Abbott Northwestern), Michigan Medicine Laboratories (MLabs), ARUP Laboratories.
If a cholesterol measurement is to be performed along with triglycerides, but not part of a lipid panel, then the patient should be fasting 9-12 hours prior to collection. If the cholesterol is ordered as part of a lipid panel, then a fasting sample is not required.
The assay manufacturer Beckman Coulter advises: N-Acetyl Cysteine (NAC), when administered in therapeutic concentrations (for the treatment of acetaminophen overdose), has been determined to interfere with assays for cholesterol and uric acid where "NAC interference may lead to falsely low results." According to Beckman Coulter, the NAC interference should be insignificant by 12 hours after completion of the initial loading dose of an IV infusion treatment regimen consisting of an initial loading dose of 150 mg/kg administered over 1 hour, a second dose of 50 mg/kg administered over 4 hours and a third dose of 100 mg/kg administered over 16 hours.
CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.
- Advanced Lipid Panel with Inflammation, Cardio IQ®
Quest DiagnosticsTest code 94220CPT 80061, 82172, 83695, 83698, 83704, 861416 mL serum
- Advanced Lipid Panel, Cardio IQ®
Quest DiagnosticsTest code 92145CPT 80061, 82172, 83695, 837044 mL serum
- ASCVD Risk Panel with Score
Quest DiagnosticsTest code 92053CPT 800612 mL serum
- Cardio IQ® ASCVD Risk Panel with Score
Quest DiagnosticsTest code 92052CPT 800612 mL serum
- Cardio IQ® Diabetes and ASCVD Risk Panel with Scores
Quest DiagnosticsTest code 92063CPT 80061, 82947, 830364 mL serum collected in a Serum separator tube (SST) and 1 mL whole blood collec
- Cardio IQ® Diabetes Risk Panel with Score
Quest DiagnosticsTest code 92026CPT 80061, 82947, 830364 mL serum collected in a Serum separator tube (SST) and 1 mL whole blood collec
- Cardiometabolic Disease Assessment (CMDA) Panel
Quest DiagnosticsTest code 14273CPT 80053, 80061, 82043, 82172, 82570, 83036, 83525, 84443, 84681, 850494.5 mL serum and
- Cardiorenal-Glycemic Status
LabcorpTest code 245292CPT 80061, 82043, 82565, 82570, 83036Urine, serum, and whole bloodTAT Within 1 day
- Diabetes and ASCVD Risk Panel with Scores
Quest DiagnosticsTest code 92062CPT 80061, 82947, 830364 mL serum collected in a serum separator tube (SST) and 1 mL whole blood collec
- Diabetes Comorbidity Assessment
LabcorpTest code 023400CPT 80061, 82043, 82565, 82570Serum (preferred) or plasma and random urineTAT Within 1 day
- Diabetes Risk Panel with Score
Quest DiagnosticsTest code 92027CPT 80061, 82947, 830364 mL serum collected in a serum separator tube (SST) and 1 mL whole blood collec
- Diabetes Risk Panel without Score
Quest DiagnosticsTest code 91920CPT 80061, 82947, 830363 mL serum collected in a serum separator tube (SST) and 1 mL whole blood collec
- Diabetes, Newly Diagnosed and Monitoring Panel
Quest DiagnosticsTest code 91712CPT 80061, 80076, 82043, 82565, 82570, 82947, 830361 mL serum collected in a serum separator tube (SST) and
- Extended Lipid Panel With LDL-C Equivalent Calculation from Apolipoprotein B (ApoB)
LabcorpTest code 167651CPT 80061, 82172Serum (preferred) or plasmaTAT 1 - 2 days
- Familial Hypercholesterolemia Lipid Profile With Interpretation
LabcorpTest code 409500CPT 80061Serum (preferred) or plasmaTAT Within 1 day
- Lipid Cascade With Reflex to Apolipoprotein B
LabcorpTest code 363676CPT 80061Serum (preferred) or plasmaTAT Within 1 day
- Lipid Cascade With Reflex to Lipoprotein Particle Assessment by NMR (With Graph if Reflexed)
LabcorpTest code 123836CPT 80061Lipid profile: Serum (preferred) or plasmaTAT Within 1 day
- Lipid Cascade With Reflex to Lipoprotein Particle Assessment by NMR (Without Graph)
LabcorpTest code 361946CPT 80061Lipid profile: Serum (preferred) or plasmaTAT Within 1 day
- Lipid panel
Allina Health Laboratory (Abbott Northwestern)Test code 160CPT 80061Lithium heparin (Li hep) plasmaTAT 1 day
- Lipid Panel
LabcorpTest code 303756CPT 80061Serum (preferred) or plasmaTAT Within 1 day
- Lipid Panel
Michigan Medicine Laboratories (MLabs)Test code LIPIDCPT 800610.5 mL serumTAT 4 hours
- Lipid Panel
ARUP LaboratoriesTest code 0020421CPT 80061Plasma separator tube or serum separator tube.TAT Within 24 hours
- Lipid Panel With Apolipoprotein B (ApoB)
LabcorpTest code 123544CPT 80061, 82172Serum, NMR LipoTube (black-and-yellow-top, gel-barrier), preferred; or serum, plTAT 1 - 3 days
- Lipid Panel With Apolipoprotein B (ApoB), GlycA (Inflammation), Diabetes Risk Index (DRI)
LabcorpTest code 123567CPT 0024U, 80061, 81599, 82172Serum or plasma, shipped refrigeratedTAT 1 - 3 days
- Lipid Panel With Diabetes Risk Index (DRI)
LabcorpTest code 123525CPT 80061, 81599Serum or plasma, shipped refrigeratedTAT 1 - 3 days
- Lipid Panel With GlycA (Inflammation)
LabcorpTest code 123510CPT 0024U, 80061Serum or plasma, shipped refrigeratedTAT 1 - 3 days
- Lipid Panel With GlycA (Inflammation) and Diabetes Risk Index (DRI)
LabcorpTest code 123559CPT 0024U, 80061, 81599Serum or plasma, shipped refrigeratedTAT 1 - 3 days
- Lipid Panel With LDL:HDL Ratio
LabcorpTest code 235010CPT 80061Serum (preferred) or plasmaTAT Within 1 day
- Lipid Panel with Ratios
Quest DiagnosticsTest code 19543CPT 800611 mL serum
- Lipid Panel with Reflex to Direct LDL
Quest DiagnosticsTest code 14852CPT 800612 mL serum
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.