Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Lipid Panel With Diabetes Risk Index (DRI)

Lipid Panel With Diabetes Risk Index (DRI): Labcorp test 123525

Labcorp test 123525, CPT 80061, 81599. Specimen: Serum or plasma, shipped refrigerated. Turnaround: 1 - 3 days.

Lipid Panel With Diabetes Risk Index (DRI) is Labcorp test code 123525, billed with CPT 80061, 81599. Specimen: Serum or plasma, shipped refrigerated. Turnaround time: 1 - 3 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code123525
CPT80061; 81599
LOINC13457-7, 2085-9, 2093-3, 2571-8, 43396-1
SpecimenSerum or plasma, shipped refrigerated
Volume1 mL
Minimum volume0.5 mL ( Note : This volume does not allow for repeat testing.)
ContainerPlain red-top tube (preferred); NMR LipoTube (black-and- yellow-top tube), lavender-top (EDTA-no gel) tube or green-top (heparin-no gel) tube is acceptable
Turnaround time1 - 3 days
Storage / transportKeep specimens refrigerated at 2°C to 8°C until shipment to the laboratory, and ship with frozen cool packs. Do not store at room temperature. Frozen storage and/or shipment of specimens is acceptable.

Test includes

This test includes cholesterol, total; DRI; high-density lipoprotein (HDL) cholesterol; low-density lipoprotein (LDL) cholesterol (calculation); non-high-density lipoprotein (non-HDL) cholesterol (calculation = total cholesterol minus HDLC); and triglycerides.

Use

The Diabetes Risk Index (DRI) is intended for use in adult subjects for the quantitative determination of a risk score in serum or plasma. The DRI score (1-100) may be used as an aid in stratifying the risk of developing type 2 diabetes in individuals with normo-glycemia or prediabetes. The Diabetes Risk Index (DRI) is a nuclear magnetic resonance spectroscopy (NMR)-derived multimarker score (values 1-100) that predicts a patient's risk of developing type 2 diabetes mellitus (T2D) independent of glycemic status. DRI derives its performance from the weighted addition of the Lipoprotein Insulin Resistance Index (LP-IR) scores with simultaneously-measured levels of branched-chain amino acids…

Methodology

Nuclear magnetic resonance (NMR) Note: The NMR method for Triglycerides, unlike the routine chemical method, is not affected by endogenous glycerol, which might be found in very rare clinical conditions such as Hyperglycerolemia (glycerol kinase deficiency-GKD), an X-linked genetic disorder. Large quantitative differences in the chemical and NMR method results may be attributable to high blood glycerol.

Collection instructions

Collect specimen in plain red-top tube (no gel), which is the preferred specimen. Hold tube upright at room temperature for 45 minutes and allow to clot. Centrifuge specimen after clotting according to manufacturer's specifications. Transfer to a transport tube for storage at (2°C to 8°C) until shipped. For NMR LipoTube (black-and-yellow-top tube), keep upright at room temperature for 30 minutes and allow to clot. Centrifuge at 1600 to 1800 xg for 10 to 15 minutes immediately after clotting. If the sample cannot be centrifuged immediately, it must be refrigerated at (2°C to 8°C) and centrifuged within 24 hours of collection. The NMR tube should then be stored at (2°C to 8°C) until shipped. Separate plasma from lavender-top (EDTA-no gel) tube or green-top (heparin-no gel) tube immediately after collection and transfer to a plastic transport tube for shipment to the laboratory. Serum or plasma drawn in gel-barrier collection tubes other than the NMR LipoTube should not be used.

Stability

TemperaturePeriod
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x5

Patient preparation

Patient should be fasting for a minimum of eight to 12 hours.

Causes for rejection

Uncentrifuged NMR LipoTube or unseparated plain serum or EDTA plasma tube; serum or plasma specimen drawn in gel-barrier collection tube other than the NMR LipoTube; gross hemolysis; specimen more than 14 days post-collection

Limitations

If triglyceride level is >800 mg/dL, LDL cholesterol will not be calculated. DRI measurements from plasma specimens are on average 8 points lower than from serum specimens. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
Cholesterol, Totalmg/dL2093-3
Triglyceridesmg/dL2571-8
HDL-Cmg/dL2085-9
Non-HDL Cholesterolmg/dL43396-1
LDL-C (NIH Calc)mg/dL13457-7

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 80061, 81599

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation