Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Diabetes Risk Panel without Score

Diabetes Risk Panel without Score: Quest Diagnostics test 91920

Quest Diagnostics test 91920, CPT 80061, 82947, 83036. Specimen: 3 mL serum collected in a serum separator tube (SST) and 1 mL whole blood collected in an EDTA (lavender-top) tube.

Diabetes Risk Panel without Score is Quest Diagnostics test code 91920, billed with CPT 80061, 82947, 83036. Specimen: 3 mL serum collected in a serum separator tube (SST) and 1 mL whole blood collected in an EDTA (lavender-top) tube. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Labcorp, Allina Health Laboratory (Abbott Northwestern), Michigan Medicine Laboratories (MLabs), ARUP Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code91920
CPT80061, 83036, 82947
LOINC—
Specimen3 mL serum collected in a serum separator tube (SST) and 1 mL whole blood collected in an EDTA (lavender-top) tube
Minimum volume1 mL serum • 0.5 mL whole blood
ContainerSerum: Serum separator tube (SST) Whole blood: EDTA (lavender-top) tube
Storage / transportRoom temperature

Methodology

See individual tests

Stability

Serum Room temperature: 48 hours Refrigerated: 5 days Frozen: 28 days Whole blood Room temperature: 7 days Refrigerated: 7 days Frozen: 6 months

Patient preparation

If a cholesterol measurement is to be performed along with triglycerides, but not part of a lipid panel, then the patient should be fasting 9-12 hours prior to collection. If the cholesterol is ordered as part of a lipid panel, then a fasting sample is not required. The assay manufacturer Beckman Coulter advises: N-Acetyl Cysteine (NAC), when administered in therapeutic concentrations (for the treatment of acetaminophen overdose), has been determined to interfere with assays for cholesterol and uric acid where "NAC interference may lead to falsely low results." According to Beckman Coulter, the NAC interference should be insignificant by 12 hours after completion of the initial loading dose of an IV infusion treatment regimen consisting of an initial loading dose of 150 mg/kg administered over 1 hour, a second dose of 50 mg/kg administered over 4 hours and a third dose of 100 mg/kg administered over 16 hours.

Reference range

See individual tests

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 80061, 82947, 83036

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation