Advanced Lipid Panel with Inflammation, Cardio IQ®: Quest Diagnostics test 94220
Quest Diagnostics test 94220, CPT 80061, 82172, 83695, 83698, 83704, 86141. Specimen: 6 mL serum.
Also known as: CardioIQ®; Cardio IQ® Advanced Lipid Panel and Inflammation Panel
Methodology
Enzymatic • Immunoassay (IA) • Immunoturbidimetric Assay • Ion Mobility • Nephelometry • Spectrophotometry (SP)
Collection instructions
The assay manufacturer Beckman Coulter advises: "N-Acetyl Cysteine (NAC), when administered in therapeutic concentrations (for the treatment of acetaminophen overdose), has been...determined to interfere with assays for...Cholesterol, Uric Acid" where "NAC interference may lead to falsely low results." According to Beckman Coulter, the NAC interference should be insignificant by 12 hours after completion of the initial loading dose of an IV infusion treatment regimen consisting of an initial loading dose of 150 mg/kg administered over 1 hr, a second dose of 50 mg/kg administered over 4 hrs and a third dose of 100 mg/kg administered over 16 hrs.
Stability
| Temperature | Period |
|---|---|
| Room temperature | 24 hours |
| Refrigerated | 7 days |
| Frozen | 28 days |
Patient preparation
If a cholesterol measurement is to be performed along with triglycerides, but not part of a lipid panel, then the patient should be fasting 9-12 hours prior to collection. If the cholesterol is ordered as part of a lipid panel, then a fasting sample is not required. The assay manufacturer Beckman Coulter advises: N-Acetyl Cysteine (NAC), when administered in therapeutic concentrations (for the treatment of acetaminophen overdose), has been determined to interfere with assays for cholesterol and uric acid where "NAC interference may lead to falsely low results." According to Beckman Coulter, the NAC interference should be insignificant by 12 hours after completion of the initial loading dose of an IV infusion treatment regimen consisting of an initial loading dose of 150 mg/kg administered over 1 hour, a second dose of 50 mg/kg administered over 4 hours and a third dose of 100 mg/kg administered over 16 hours.
Causes for rejection
Hemolysis • Moderate to grossly lipemic • Icteric
Reference range
See Laboratory Report
Notices
CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.
Assay category
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.
View this test on Quest Diagnostics's website → · Last checked 2026-11-29
Other tests billed with CPT 80061, 82172, 83695
- Advanced Lipid Panel, Cardio IQ®
- ASCVD Risk Panel with Score
- Cardiorenal-Glycemic Status
- Diabetes Comorbidity Assessment
- Extended Lipid Panel With LDL-C Equivalent Calculation from Apolipoprotein B (ApoB)
- Familial Hypercholesterolemia Lipid Profile With Interpretation
- Lipid Cascade With Reflex to Apolipoprotein B
- Lipid Cascade With Reflex to Lipoprotein Particle Assessment by NMR (With Graph if Reflexed)
- Lipid Cascade With Reflex to Lipoprotein Particle Assessment by NMR (Without Graph)
- Lipid Panel
- Lipid Panel
- Lipid Panel
- Lipid Panel With Apolipoprotein B (ApoB)
- Lipid Panel With Apolipoprotein B (ApoB), GlycA (Inflammation), Diabetes Risk Index (DRI)
- Lipid Panel With Diabetes Risk Index (DRI)
- Lipid Panel With GlycA (Inflammation)
- Lipid Panel With GlycA (Inflammation) and Diabetes Risk Index (DRI)
- Lipid Panel With LDL:HDL Ratio
- Lipid Panel With Total Cholesterol:HDL Ratio
- Lipid Panel, Extended
- Lipid Panel, Fasting
- Lipid Panel, Nonfasting
- Lipid Profile With Non-HDL Cholesterol
- Lipid Profile, Fasting, Pediatric
- LipoFit by NMR
- Lipoprotein Electrophoresis
- Lipoprotein Electrophoresis
- Lipoprotein Phenotyping Profile
- Lipoprotein Profile
- NMR LipoProfile® With Lipids (With Graph)
Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation