Quest Diagnostics test 94220, CPT 80061, 82172, 83695, 83698, 83704, 86141. Specimen: 6 mL serum.

Advanced Lipid Panel with Inflammation, Cardio IQ® is Quest Diagnostics test code 94220, billed with CPT 80061, 82172, 83695, 83698, 83704, 86141. Specimen: 6 mL serum. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Labcorp, Michigan Medicine Laboratories (MLabs), ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code94220
CPT80061, 83704, 82172, 83695, 86141, 83698
LOINC—
Specimen6 mL serum Minimum volume 3 mL
ContainerTransport tube
Storage / transportRefrigerated (cold packs)

Also known as: CardioIQ®; Cardio IQ® Advanced Lipid Panel and Inflammation Panel

Methodology

Enzymatic • Immunoassay (IA) • Immunoturbidimetric Assay • Ion Mobility • Nephelometry • Spectrophotometry (SP)

Collection instructions

The assay manufacturer Beckman Coulter advises: "N-Acetyl Cysteine (NAC), when administered in therapeutic concentrations (for the treatment of acetaminophen overdose), has been...determined to interfere with assays for...Cholesterol, Uric Acid" where "NAC interference may lead to falsely low results." According to Beckman Coulter, the NAC interference should be insignificant by 12 hours after completion of the initial loading dose of an IV infusion treatment regimen consisting of an initial loading dose of 150 mg/kg administered over 1 hr, a second dose of 50 mg/kg administered over 4 hrs and a third dose of 100 mg/kg administered over 16 hrs.

Stability

TemperaturePeriod
Room temperature24 hours
Refrigerated7 days
Frozen28 days

Patient preparation

If a cholesterol measurement is to be performed along with triglycerides, but not part of a lipid panel, then the patient should be fasting 9-12 hours prior to collection. If the cholesterol is ordered as part of a lipid panel, then a fasting sample is not required. The assay manufacturer Beckman Coulter advises: N-Acetyl Cysteine (NAC), when administered in therapeutic concentrations (for the treatment of acetaminophen overdose), has been determined to interfere with assays for cholesterol and uric acid where "NAC interference may lead to falsely low results." According to Beckman Coulter, the NAC interference should be insignificant by 12 hours after completion of the initial loading dose of an IV infusion treatment regimen consisting of an initial loading dose of 150 mg/kg administered over 1 hour, a second dose of 50 mg/kg administered over 4 hours and a third dose of 100 mg/kg administered over 16 hours.

Causes for rejection

Hemolysis • Moderate to grossly lipemic • Icteric

Reference range

See Laboratory Report

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 80061, 82172, 83695

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation