Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Influenza A and B Virus with Subtyping, Real-Time PCR

Influenza A and B Virus with Subtyping, Real-Time PCR: Quest Diagnostics test 91335

Quest Diagnostics test 91335, CPT 87502, 87503. Specimen: Nasal or nasopharyngeal swab submitted in 3 mL M4 media or VCM medium (green-cap) tube, or UTM equivalent.

Influenza A and B Virus with Subtyping, Real-Time PCR is Quest Diagnostics test code 91335, billed with CPT 87502, 87503. Specimen: Nasal or nasopharyngeal swab submitted in 3 mL M4 media or VCM medium (green-cap) tube, or UTM equivalent. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Labcorp, Cleveland Clinic Laboratories, Allina Health Laboratory (Abbott Northwestern), OHSU Laboratory Services.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code91335
CPT87502, 87503 (x3)
LOINC—
SpecimenNasal or nasopharyngeal swab submitted in 3 mL M4 media or VCM medium (green-cap) tube, or UTM equivalent
Minimum volume0.6 mL
ContainerM4, VCM, UTM equivalent or plastic leak-proof container
Storage / transportRefrigerated (cold packs)

Methodology

Real-Time Polymerase Chain Reaction • Real-Time Reverse Transcriptase Polymerase Chain Reaction (RT-PCR)

Collection instructions

Swabs in VCM, M4 or UTM tranport media: Use only sterile dacron or rayon swabs. Do not use calcium alginate swabs, as they may contain substances that inhibit PCR testing. Break applicator stick off near the tip to permit tightening of the cap. Nasopharyngeal aspirate: Submit in a sterile container with a leak-proof cap.

Stability

TemperaturePeriod
Room temperature48 hours
Refrigerated7 days
Frozen30 days

Causes for rejection

Calcium alginate swabs

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Alternative specimen(s)

3 mL nasopharyngeal aspirate submitted in a sterile leak-proof container

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 87502, 87503

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation