Influenza A and B RNA, Qualitative RT-PCR, Respiratory with Reflex to H5: Quest Diagnostics test 18201
Quest Diagnostics test 18201, CPT 87502. Specimen: Nasopharyngeal swab or anterior nares or oropharyngeal swab submitted in a 3 mL VCM (green-cap) or equivalent (UTM) tube.
Also known as: H5N1; Avian Influenza A H5N1; H5; Avian Flu; Flu A; Flu A/B; Flu B
Methodology
Real-Time Reverse Transcriptase Polymerase Chain Reaction (RT-PCR)
Collection instructions
Each Influenza type A/B RNA with reflex to H5 specimen should be accompanied by its own separate requisition and transported in its own sealed bag. This test is not approved for observed-self collection at Quest Patient Service Centers.
Stability
Swabs Room temperature: Unacceptable Refrigerated: 4 days Frozen -20° C: Unacceptable Frozen -70° C: 30 days Bronchial lavage/wash Room temperature: Unacceptable Refrigerated: 4 days Frozen -20° C: Unacceptable Frozen -70° C: 30 days
Causes for rejection
Calcium alginate swabs • Wooden shafted swabs • Nasal specimens
Assay category
This test is not available for New York patient testing.
Alternative specimen(s)
1 mL bronchial lavage/wash collected in a sterile leak-proof container
View this test on Quest Diagnostics's website → · Last checked 2026-11-29
Other tests billed with CPT 87502
- Influenza A (H5) Virus by Qualitative NAAT
- Influenza A and B RNA, Qualitative Real-Time PCR
- Influenza A and B RNA, Qualitative RT-PCR, Conjunctiva with Reflex to H5
- Influenza A and B Virus with Subtyping, Real-Time PCR
- Influenza A and Influenza B With Reflex to H5 Subtyping, NAA
- Influenza A and Influenza B, NAA
- Influenza A Subtyping by Sequencing
- Influenza A/B PCR
- Influenza A/B PCR, RAPID
Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation