Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Influenza A and Influenza B With Reflex to H5 Subtyping, NAA

Influenza A and Influenza B With Reflex to H5 Subtyping, NAA: Labcorp test 140046

Labcorp test 140046, CPT 87502. Specimen: Nasopharyngeal swab. Turnaround: 2 - 4 days.

Influenza A and Influenza B With Reflex to H5 Subtyping, NAA is Labcorp test code 140046, billed with CPT 87502. Specimen: Nasopharyngeal swab. Turnaround time: 2 - 4 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code140046
CPT87502
LOINC38272-1, 76078-5, 85478-6, 97733-0
SpecimenNasopharyngeal swab
Volume1 swab
Minimum volume1 swab
ContainerUniversal or Viral Transport Media (UTM or VTM)
Turnaround time2 - 4 days
Storage / transportFreeze.

Use

This test detects influenza A and influenza B by nucleic acid amplification. If influenza A is detected, a second test will be performed to confirm the presence of influenza A and to determine if the subtype is H5. This test should be used only for patients who meet the most current clinical and epidemiological criteria for H5-specific testing, as recommended by the U.S. Centers for Disease Control and Prevention. This test is validated for nasopharyngeal (NP) collections only and is intended to be used for patients presenting with respiratory symptoms consistent with influenza-like illness (ILI). Patients at risk for Influenza A/H5 and who have conjunctival symptoms only may not show a…

Methodology

Nucleic Acid Amplification

Collection instructions

Collect NP swab per standard techniques and immediately place swab in up to 3 mL of universal or viral transport media.

Stability

TemperaturePeriod
Room Temperature24 hours
Refrigerated72 hours (3 days)
Frozen-70°C or lower = 14 days
Freeze/Thaw cyclesStable x2

Causes for rejection

Improper collection; inadequate specimen; improper labeling; specimen leaked in transit; quantity not sufficient for analysis; name discrepancies; specimen exceeding storage requirements; nasal swabs or any other upper respiratory sample other than nasopharyngeal swab in universal or viral transport media; samples submitted in non-approved transport devices

Special instructions

If reflex test is performed, additional charges/CPT code(s) may apply.

Limitations

This test detects influenza A, influenza B and sequences for the H5 subtype. Non-H5 subtypes will not be detected in this assay. Influenza A/H5 is currently very rarely found in humans in the U.S. Results from this test must be correlated with the clinical history, epidemiological data and other data available to the clinician evaluating the patient. Viral and bacterial nucleic acids may persist in vivo independent of organism viability. Detection of organism target(s) does not imply that the corresponding organisms are infectious or are the causative agents for clinical symptoms. The detection of viral and bacterial nucleic acid is dependent upon proper specimen collection, handling,…

LOINC map

Result codeResult nameUnitsResult LOINC
140104Influenza A RNA76078-5
140106Influenza B RNA85478-6
140113FluA/H5 subtype Rflx38272-1

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 87502

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation