Influenza A/B PCR: Allina Health Laboratory (Abbott Northwestern) test 8810

Allina Health Laboratory (Abbott Northwestern) test 8810, CPT 87502. Specimen: Nasal or Nasopharyngeal swab - (Allina Health Clinic Ambulatory patients only). Turnaround: Inpatient - 2 hours.

Influenza A/B PCR is Allina Health Laboratory (Abbott Northwestern) test code 8810, billed with CPT 87502. Specimen: Nasal or Nasopharyngeal swab - (Allina Health Clinic Ambulatory patients only). Turnaround time: Inpatient - 2 hours. Performing laboratory: Allina Health Laboratory (Abbott Northwestern), CLIA 24D0401558 (Minneapolis, MN). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Labcorp, Cleveland Clinic Laboratories, OHSU Laboratory Services.
LaboratoryAllina Health Laboratory (Abbott Northwestern)
CLIA number24D0401558
Test code8810
CPT87502
LOINC—
SpecimenNasal or Nasopharyngeal swab - (Allina Health Clinic Ambulatory patients only)
ContainerFor Allina Health Clinic Ambulatory patients only: RespDirect (Enhanced Direct Load Tube) For all other patients: Copan UTM-RT
Turnaround timeInpatient - 2 hours Outpatient - 12 hours

Also known as: Flu test

Use

Aiding in diagnosis of influenza in patients with signs and symptoms of influenza-like-illness (ILI). Limitations: This assay will detect Avian Influenza (positive for Influenza A), however, if confirmation of the Avian Influenza specifically is required, the provider will need to work with the MN Department of Health directly to arrange for typing. MLS Laboratory Update: Guidance for Highly Pathogenic Avian Influenza (HPAI) Testing

Methodology

Real-Time Polymerase Chain Reaction (RT-PCR)

Collection instructions

For Allina Health Clinic Ambulatory patients: Nasal collection Note: Swab included in RespDirect (Enhanced Direct Load Tube) kit is also acceptable for nasopharyngeal collections. See NP collection instructions below. Insert swab in one nostril 1/2”-3/4” until swab tip is no longer visible. Rotate the swab using moderate pressure along the nostril wall at least 4 times. Complete the collection by swabbing the other nostril in the same fashion. Uncap the transport media, insert the swab into the media, break swab against the tube at the score line, recap. For all other patients: Nasopharyngeal (NP) swab collection: Use the mini-tip NP swab included with the UTM packaging. Tip the patient’s head back. Gently insert the NP swab into the nostril parallel to the palate (not upwards) until resistance is encountered or the distance is equivalent to that from the ear to the nostril of the patient, indicating contact with the nasopharynx. If any resistance is met in the passageways, do not force the swab; back off and try reinserting it at a different angle, closer to the floor of the nasal canal, or try the other nostril. Gently rub and roll the swab for 10-15 seconds while the swab is in contact with the nasopharyngeal wall. The CDC recommends leaving the swab in place for several seconds to absorb secretions. Slowly remove the swab and place in the transport medium. Break the swab shaft so that it fits into the medium container and recap tightly. Label the specimen appropriately. Document the source “NP” on the label. New England Journal of Medicine video on NP swab collection: Nasopharyngeal Swab Collection Video

Stability

RespDirect (Enhanced Direct Load Tube) - (Allina Health Clinic Ambulatory) Refrigerated - 6 days Ambient - 6 days Universal Transport Media (UTM) Refrigerated (2-8°C) - 7 days

Patient preparation

Please have patient blow their nose prior to NP and nasal collections. Excessive mucus is known inhibitor/interfering substance for molecular testing.

Causes for rejection

Oropharyngeal specimens Improper label (unlabeled or mislabeled) Swabs other than nasopharyngeal (NP) or nasal Time delay between time of collection and receipt of specimen Improper transport container Improper transport temperature Interfering substances Inappropriate specimen type Leaking container

Reference range

Negative

Performed

Daily

Abbreviation

INP

Order number

LAB8810

Transport container

RespDirect (Enhanced Direct Load Tube) - Allina Health Clinic Ambulatory Patients only Universal Transport Media (UTM)

Performing Laboratory

AHL - Microbiology: M

View this test on Allina Health Laboratory (Abbott Northwestern)'s website → · Last checked 2026-11-29

Other tests billed with CPT 87502

Search the National Lab Test Directory · All Allina Health Laboratory (Abbott Northwestern) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation