Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Lactate Dehydrogenase (LD) Isoenzyme Panel

Lactate Dehydrogenase (LD) Isoenzyme Panel: Quest Diagnostics test 4411

Quest Diagnostics test 4411, CPT 83615, 83625. Specimen: 2 mL serum collected in a serum separator tube (SST).

Lactate Dehydrogenase (LD) Isoenzyme Panel is Quest Diagnostics test code 4411, billed with CPT 83615, 83625. Specimen: 2 mL serum collected in a serum separator tube (SST). Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: OHSU Laboratory Services, Labcorp, Cleveland Clinic Laboratories, Allina Health Laboratory (Abbott Northwestern), ARUP Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code4411
CPT83615, 83625
LOINC—
Specimen2 mL serum collected in a serum separator tube (SST)
Minimum volume1 mL
ContainerTransport tube Transport temperature Room temperature Specimen stability Room temperature: 7 days Refrigerated: Unacceptable Frozen: Unacceptable

Methodology

Electrophoresis • Spectrophotometry (SP)

Collection instructions

Centrifuge serum specimens within 1 hour of collection, transfer serum to a clean, plastic, transport tube(s), and transport at room temperature to the laboratory. Do not refrigerate or freeze the specimens. Specimens cannot be shared, and no other tests should be ordered with Lactate Dehydrogenase Isoenzymes.

Causes for rejection

Hemolysis • Received refrigerated • Received frozen

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 83615, 83625

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation