Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Allina Health Laboratory (Abbott Northwestern) › Lactate dehydrogenase (LD), pericardial, peritoneal or pleural fluid

Lactate dehydrogenase (LD), pericardial, peritoneal or pleural fluid: Allina Health Laboratory (Abbott Northwestern) test 156

Allina Health Laboratory (Abbott Northwestern) test 156, CPT 83615. Specimen: Fluid:. Turnaround: 1 day.

Lactate dehydrogenase (LD), pericardial, peritoneal or pleural fluid is Allina Health Laboratory (Abbott Northwestern) test code 156, billed with CPT 83615. Specimen: Fluid:. Turnaround time: 1 day. Performing laboratory: Allina Health Laboratory (Abbott Northwestern), CLIA 24D0401558 (Minneapolis, MN). Other labs in the directory with tests billed under the same CPT: OHSU Laboratory Services, Labcorp, Cleveland Clinic Laboratories, ARUP Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryAllina Health Laboratory (Abbott Northwestern)
CLIA number24D0401558
Test code156
CPT83615
LOINC—
SpecimenFluid: Pericardial, peritoneal or pleural
Volume1.0 mL
Minimum volume0.5 mL
ContainerSterile container
Turnaround time1 day

Also known as: LDH

Use

Pleural: Pleural fluid LDH to serum LDH ratio ≤ 0.6 or less than 2/3 the upper limit of normal serum LDH is consistent with transudative effusions, while pleural fluid LDH to serum LDH ratio > 0.6 is consistent with exudative effusions. Peritoneal: Ascitic fluid LDH may be useful in differentiating secondary Bacterial peritonitis from spontaneous bacterial peritonitis when at least two of three criteria are met in ascites fluid: Total Protein > 1.0 g/dL Glucose < 50 mg/dL LDH > upper reference limit for serum

Methodology

Enzymatic

Stability

Refrigerated - 3 days

Causes for rejection

Improper labels (unlabeled or mislabeled) Hemolysis (some procedures) Delay in transport Improper storage temperature affecting results Improper container Leaking container resulting in compromised specimen Quantity not sufficient (QNS)

Reference range

Undefined

Performed

Daily

Abbreviation

LDF

Order number

83615.2

Transport container

False bottom plasma/serum transport vial/tube (AHL) Required forms/information: Source (indicate on order and on transport container)

Performing Laboratory

AHL - Chemistry: C

Processing instructions

Centrifuge for 5 -10 minutes to remove any cellular material Transfer supernatant to a False bottom plasma/serum transport vial/tube (AHL) Refrigerate

View this test on Allina Health Laboratory (Abbott Northwestern)'s website → · Last checked 2026-11-29

Other tests billed with CPT 83615

Search the National Lab Test Directory · All Allina Health Laboratory (Abbott Northwestern) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation