Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Voltage-Gated Calcium Channel (VGCC) Type P/Q Antibody
Voltage-Gated Calcium Channel (VGCC) Type P/Q Antibody: Quest Diagnostics test 34057
Quest Diagnostics test 34057, CPT 86596. Specimen: 1 mL serum.
Voltage-Gated Calcium Channel (VGCC) Type P/Q Antibody is Quest Diagnostics test code 34057, billed with CPT 86596. Specimen: 1 mL serum. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Labcorp, Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code34057
CPT86596
LOINC—
Specimen1 mL serum
Minimum volume0.2 mL
ContainerTransport tube
Storage / transportRefrigerated (cold packs)
Also known as: Lambert-Eaton Test
Methodology
Radiobinding Assay (RBA)
Stability
| Temperature | Period |
|---|---|
| Room temperature | 48 hours |
| Refrigerated | 7 days |
| Frozen | 35 days |
Causes for rejection
Gross hemolysis • Lipemia • Received Room temperature • Freeze/thaw greater than 3 cycles
Reference range
<30 pmol/L
View this test on Quest Diagnostics's website → · Last checked 2026-11-29
Other tests billed with CPT 86596
- Autoimmune Cerebellar Ataxia Panel
- Autoimmune Movement Disorder Panel, Serum
- Autoimmune Neurologic Disease Panel With Reflex, Serum
- Autoimmune Neurology Antibody Comprehensive Panel with Reflexes, Serum
- Autoimmune Neurology/Comprehensive Paraneoplastic Profile
- Autoimmune Neuromuscular Junction Reflexive Panel
- Encephalitis Antibody Evaluation with Reflex to Titer and Line Blot, Serum
- Epilepsy Antibody Evaluation with Reflex to Titer and Line Blot, Serum
- Lambert-Eaton Syndrome Antibody Panel
- Movement Disorder, Autoimmune/Paraneoplastic Evaluation
- Myasthenia Gravis Evaluation, Lambert-Eaton Syndrome
- NeoComplete Paraneoplastic Evaluation with Recombx®
- P/Q-Type Voltage-Gated Calcium Channel (VGCC) Antibody
- P/Q-Type Voltage-Gated Calcium Channel (VGCC) Antibody
- P/Q-Type Voltage-Gated Calcium Channel (VGCC) Autoantibody
- Paraneoplastic Antibody Evaluation w/Reflex to Titer and Line Blot,Basic
- Paraneoplastic Antibody Expanded Evaluation w/Reflex to Titer and LB, Serum
- Paraneoplastic, Autoantibody Profile
- Voltage-Gated Calcium Channel (VGCC) Antibody Panel
- Voltage-Gated Calcium Channel (VGCC) Type N Antibody
- Voltage-gated Calcium Channel Antibody (VGCCA)
Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation