Voltage-gated Calcium Channel Antibody (VGCCA): Labcorp test 140640
Labcorp test 140640, CPT 86596. Specimen: Serum. Turnaround: 3 - 8 days.
Voltage-gated Calcium Channel Antibody (VGCCA) is Labcorp test code 140640, billed with CPT 86596. Specimen: Serum. Turnaround time: 3 - 8 days. Performing laboratory: Labcorp, CLIA
34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Quest Diagnostics, ARUP Laboratories, Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories.
Test code140640
CPT86596
LOINC31024-3
SpecimenSerum
Volume0.5 mL
Minimum volume0.4 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube or gel-barrier tube
Turnaround time3 - 8 days
Storage / transportRoom temperature
Also known as: Lambert-Eaton Myasthenic Syndrome Antibody; LEMS Autoantibody; P/Q Type VGCC; VGCC Antibody; VGCCA
Use
Measurement of P/Q-type voltage-gated calcium channel (VGCC) antibodies as an aid in the diagnosis of Lambert-Eaton myasthenic syndrome (LEMS)
Methodology
Radioimmunoassay (RIA)
Collection instructions
Serum should be separated from cells within one hour and transferred to a plastic transport tube.
Stability
| Temperature | Period |
|---|
| Room temperature | 14 days |
| Refrigerated | 14 days |
| Frozen | 14 days |
| Freeze/thaw cycles | Stable x3 |
Patient preparation
Patient should have no radioactive isotopes administered 24 hours prior to venipuncture.
Causes for rejection
Nonserum specimen; gross hemolysis; gross lipemia
Reference range
0.0–30.0 pmol/L
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|
| 140686 | VGCC Antibody | pmol/L | 31024-3 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 86596
- Autoimmune Cerebellar Ataxia Panel
Quest DiagnosticsTest code 90133CPT 82784, 86255, 86364, 865963 mL serum
- Autoimmune Movement Disorder Panel, Serum
ARUP LaboratoriesTest code 3018964CPT 84182, 86255, 86256, 86341, 86596Serum separator tube (SST)TAT 3-10 days
- Autoimmune Neurologic Disease Panel With Reflex, Serum
ARUP LaboratoriesTest code 3018965CPT 83519, 84182, 86041, 86052, 86255, 86256, 86341, 86362, 86596Serum separator tube (SST)TAT 3-10 days
- Autoimmune Neurology Antibody Comprehensive Panel with Reflexes, Serum
Quest DiagnosticsTest code 93888CPT 83519, 84182, 86041, 86255, 86341, 8659610 mL serum collected in a red-top tube (no gel)
- Autoimmune Neurology/Comprehensive Paraneoplastic Profile
LabcorpTest code 505500CPT 86051, 86255, 86341, 86596Serum (gel barrier tube or red-top tube)TAT 5 - 7 days
- Autoimmune Neuromuscular Junction Reflexive Panel
ARUP LaboratoriesTest code 3003017CPT 83516, 83519, 86041, 86042, 86043, 86255, 86256, 86596Serum separator tube (SST).TAT 2-8 days
- Movement Disorder, Autoimmune/Paraneoplastic Evaluation
Michigan Medicine Laboratories (MLabs)Test code MDS2CPT 0432U, 83516, 86255, 86341, 865964 mL serumTAT 9 - 14 days
- Myasthenia Gravis Evaluation, Lambert-Eaton Syndrome
Michigan Medicine Laboratories (MLabs)Test code MGLECPT 86041, 865963 mL serumTAT 3 - 11 days
- P/Q-Type Voltage-Gated Calcium Channel (VGCC) Antibody
ARUP LaboratoriesTest code 0092628CPT 86596Plain Red or Serum Separator Tube (SST).TAT 1-8 days
- P/Q-Type Voltage-Gated Calcium Channel (VGCC) Antibody
Michigan Medicine Laboratories (MLabs)Test code APQCCCPT 865961 mL serumTAT 2 - 10 days
- P/Q-Type Voltage-Gated Calcium Channel (VGCC) Autoantibody
Cleveland Clinic LaboratoriesTest code VOLTCACPT 86596SerumTAT 1 - 8 days
- Paraneoplastic, Autoantibody Profile
LabcorpTest code 505575CPT 86255, 86596SerumTAT 4 days
- Voltage-Gated Calcium Channel (VGCC) Antibody Panel
ARUP LaboratoriesTest code 3002046CPT 86596Plain Red or Serum Separator Tube (SST).TAT 2-9 days
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code.
Submit your lab's test menu → Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation