Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › Autoimmune Neurologic Disease Panel With Reflex, Serum

Autoimmune Neurologic Disease Panel With Reflex, Serum: ARUP Laboratories test 3018965

ARUP Laboratories test 3018965, CPT 83519, 84182, 86041, 86052, 86255, 86256, 86341, 86362, 86596. Specimen: Serum separator tube (SST). Turnaround: 3-10 days.

Autoimmune Neurologic Disease Panel With Reflex, Serum is ARUP Laboratories test code 3018965, billed with CPT 83519, 84182, 86041, 86052, 86255, 86256, 86341, 86362, 86596. Specimen: Serum separator tube (SST). Turnaround time: 3-10 days. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Quest Diagnostics, Labcorp, Cleveland Clinic Laboratories.
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code3018965
CPT83519 x2; 84182 x3; 86255 x12; 86341; 86052; 86362; 86596; if reflexed, add 86255; 84182 x4; 86041; 86256 per titer
LOINC101874-6, 33980-4, 41871-5, 42233-7, 56540-8, 61177-2, 63439-4, 72504-4
SpecimenSerum separator tube (SST)
Turnaround time3-10 days
Storage / transportFrozen

Also known as: AMPA; amphiphysin; ANNA; AQP4; CASPR2; CRMP5; CV2; dementia; DNER; DPPX; dysautonomia; encephalitis; encephalopathy; epilepsy; GABA-A; GABA-B; GAD; GAD 65; GAD65; ganglionic; Hu; IgLON5; ITPR1; LGI1; mGluR1; MOG; movement disorders; myelopathy; NMDA; paraneoplastic; PCCA; Ri; Sox-1; Tr; VGCC; VGKC; Yo

Use

Use to evaluate suspected autoimmune disease of the central and peripheral nervous system. Targeted phenotype-specific panels are preferred for the evaluation of autoimmune neurologic disease. Refer to the Autoimmune Neurologic Disease Panel With Reflex, Serum and CSF Test Fact Sheet for phenotype-specific test options. Testing in both serum and CSF is recommended for suspected encephalitis and/or paraneoplastic disorders to maximize diagnostic yield; refer to Autoimmune Neurologic Disease Panel With Reflex, CSF ( 3018967 ) for CSF testing.

Methodology

Semi-Quantitative Cell-Based Indirect Fluorescent Antibody / Qualitative Immunoblot / Quantitative Radioimmunoassay (RIA) / Semi-Quantitative Enzyme-Linked Immunosorbent Assay (ELISA) / Semi-Quantitative Indirect Fluorescent Antibody (IFA)

Collection instructions

Separate from cells ASAP or within 2 hours of collection. Transfer 4 mL serum to ARUP standard transport tube. (Min: 2.8 mL)

Stability

After separation from cells: Ambient: 24 hours; Refrigerated: 1 week; Frozen: 1 month (Three freeze/thaw cycles are acceptable)

Causes for rejection

Amniotic fluid, ocular fluid, peritoneal fluid, synovial fluid, CSF, or plasma. Contaminated, grossly hemolyzed, icteric, or lipemic specimens.

Reference range

Test Number Components Reference Interval KLHL11 Ab IgG CBA-IFA Screen, Serum Less than 1:10 Ma2/Ta Antibody, IgG by Immunoblot, Ser Negative mGluR1 Ab IgG CBA-IFA Screen, Serum Less than 1:10 IgLON5 Ab IgG CBA-IFA Screen, Serum Less than 1:10 GABA-AR Ab IgG CBA-IFA Screen, Serum Less than 1:10 DPPX Ab IgG CBA-IFA Screen, Serum Less than 1:10 Ganglionic Acetylcholine Receptor Ab 8.4 pmol/L or less SOX1 Antibody, IgG by Immunoblot, Serum Negative MOG Ab IgG CBA-IFA Screen, Serum Less than 1:10 GABA-BR Ab IgG CBA-IFA Scrn, Ser Less than 1:10 AMPA Receptor Ab IgG CBA-IFA Scrn, Serum Less than 1:10 CV2 Ab IgG CBA-IFA Screen, Serum Less than 1:100 NMO/AQP4 Ab IgG CBA-IFA Screen, Serum Less than 1:10 LGI1 Ab IgG CBA-IFA Screen, Serum Less than 1:10 CASPR2 Ab IgG CBA-IFA Screen, Serum Less than 1:10 Purkinje Cell/Neuronal Nuclear IgG Scrn None Detected Voltage-Gated Potassium Channel Ab, Ser 31 pmol/L or less NMDA Receptor Ab IgG CBA-IFA, Serum Less than 1:10 Glutamic Acid Decarboxylase Antibody 0.0-5.0 IU/mL P/Q-Type Calcium Channel Antibody 24.5 pmol/L or less Neuronal Antibody (Amphiphysin) Negative

Performed

Tue

Compliance Category

Laboratory Developed Test (LDT)

New York DOH Approval Status

This test is New York state approved.

LOINC map

Result codeResult nameUnitsResult LOINC
0051709Neuronal Antibody (Amphiphysin)94385-2
0092629P/Q-Type Calcium Channel Antibody33980-4
2001772Glutamic Acid Decarboxylase Antibody56540-8
2004222NMDA Receptor Ab IgG CBA-IFA, Serum80221-5
2004890Voltage-Gated Potassium Channel Ab, Ser41871-5
2007962Purkinje Cell/Neuronal Nuclear IgG Scrn61177-2
2009453CASPR2 Ab IgG CBA-IFA Screen, Serum82979-6
2009457LGI1 Ab IgG CBA-IFA Screen, Serum82978-8
2013322NMO/AQP4 Ab IgG CBA-IFA Screen, Serum63439-4
2013959CV2 Ab IgG CBA-IFA Screen, Serum72504-4
3001261AMPA Receptor Ab IgG CBA-IFA Scrn, Serum82733-7
3001271GABA-BR Ab IgG CBA-IFA Scrn, Ser93428-1
3001278MOG Ab IgG CBA-IFA Screen, Serum91545-4
3002903SOX1 Antibody, IgG by Immunoblot, Serum82444-1
3003019Ganglionic Acetylcholine Receptor Ab42233-7
3004361DPPX Ab IgG CBA-IFA Screen, Serum94676-4
3006009GABA-AR Ab IgG CBA-IFA Screen, Serum101874-6
3006019IgLON5 Ab IgG CBA-IFA Screen, Serum96478-3
3006045mGluR1 Ab IgG CBA-IFA Screen, Serum93498-4
3017505Ma2/Ta Antibody, IgG by Immunoblot, Ser82423-5
3018734KLHL11 Ab IgG CBA-IFA Screen, Serum99072-1

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 83519, 84182, 86041

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation