P/Q-Type Voltage-Gated Calcium Channel (VGCC) Antibody: Michigan Medicine Laboratories (MLabs) test APQCC
Michigan Medicine Laboratories (MLabs) test APQCC, CPT 86596. Specimen: 1 mL serum. Turnaround: 2 - 10 days.
P/Q-Type Voltage-Gated Calcium Channel (VGCC) Antibody is Michigan Medicine Laboratories (MLabs) test code APQCC, billed with CPT 86596. Specimen: 1 mL serum. Turnaround time: 2 - 10 days. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA
23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: Quest Diagnostics, ARUP Laboratories, Labcorp, Cleveland Clinic Laboratories.
Test codeAPQCC
CPT86596
LOINC—
Specimen1 mL serum
Volume1 mL serum
Turnaround time2 - 10 days
Storage / transportAfter separation from cells: Ambient: 8 hours; Refrigerated: 2 weeks; Frozen: Indefinitely.
Also known as: P/Q-Type Voltage Gated Calcium Channel Antibody; Voltage gated Calcium Channel Ab
Collection instructions
Collect specimen in a red top or SST tube. Centrifuge and aliquot serum into a plastic vial within 2 hours of collection. Refrigerate
Reference range
Negative: 0.0-24.5 pmol/L, Indeterminate: 24.6-45.6 pmol/L, Positive: 45.7 pmol/L or greater
Section
Sendout Testing
Performed
Tuesday
NY State approved
No
Performing Laboratory
Sendout Testing
View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29
Other tests billed with CPT 86596
- Autoimmune Cerebellar Ataxia Panel
Quest DiagnosticsTest code 90133CPT 82784, 86255, 86364, 865963 mL serum
- Autoimmune Movement Disorder Panel, Serum
ARUP LaboratoriesTest code 3018964CPT 84182, 86255, 86256, 86341, 86596Serum separator tube (SST)TAT 3-10 days
- Autoimmune Neurologic Disease Panel With Reflex, Serum
ARUP LaboratoriesTest code 3018965CPT 83519, 84182, 86041, 86052, 86255, 86256, 86341, 86362, 86596Serum separator tube (SST)TAT 3-10 days
- Autoimmune Neurology Antibody Comprehensive Panel with Reflexes, Serum
Quest DiagnosticsTest code 93888CPT 83519, 84182, 86041, 86255, 86341, 8659610 mL serum collected in a red-top tube (no gel)
- Autoimmune Neurology/Comprehensive Paraneoplastic Profile
LabcorpTest code 505500CPT 86051, 86255, 86341, 86596Serum (gel barrier tube or red-top tube)TAT 5 - 7 days
- Autoimmune Neuromuscular Junction Reflexive Panel
ARUP LaboratoriesTest code 3003017CPT 83516, 83519, 86041, 86042, 86043, 86255, 86256, 86596Serum separator tube (SST).TAT 2-8 days
- Movement Disorder, Autoimmune/Paraneoplastic Evaluation
Michigan Medicine Laboratories (MLabs)Test code MDS2CPT 0432U, 83516, 86255, 86341, 865964 mL serumTAT 9 - 14 days
- Myasthenia Gravis Evaluation, Lambert-Eaton Syndrome
Michigan Medicine Laboratories (MLabs)Test code MGLECPT 86041, 865963 mL serumTAT 3 - 11 days
- P/Q-Type Voltage-Gated Calcium Channel (VGCC) Antibody
ARUP LaboratoriesTest code 0092628CPT 86596Plain Red or Serum Separator Tube (SST).TAT 1-8 days
- P/Q-Type Voltage-Gated Calcium Channel (VGCC) Autoantibody
Cleveland Clinic LaboratoriesTest code VOLTCACPT 86596SerumTAT 1 - 8 days
- Paraneoplastic, Autoantibody Profile
LabcorpTest code 505575CPT 86255, 86596SerumTAT 4 days
- Voltage-Gated Calcium Channel (VGCC) Antibody Panel
ARUP LaboratoriesTest code 3002046CPT 86596Plain Red or Serum Separator Tube (SST).TAT 2-9 days
- Voltage-gated Calcium Channel Antibody (VGCCA)
LabcorpTest code 140640CPT 86596SerumTAT 3 - 8 days
Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code.
Submit your lab's test menu → Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation