Quest Diagnostics test 30340, CPT 86146.

Beta-2-Glycoprotein I Antibodies (IgG, IgA, IgM) is Quest Diagnostics test code 30340, billed with CPT 86146. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Labcorp, Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code30340
CPT86146 (x3)
LOINC—
Minimum volume1.5 mL
ContainerTransport tube Transport temperature Room temperature Specimen stability Room temperature: 5 days Refrigerated: 14 days Frozen: 30 days

Methodology

Immunoassay (IA)

Collection instructions

Plasma: Centrifuge light blue-top tube 15 minutes at approximately 1500 g within 60 minutes of collection. Using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic vial. Centrifuge a second time and transfer platelet-poor plasma into a new plastic vial. Plasma must be free of platelets (<10,000/mcL).

Patient preparation

None Specified Preferred specimen(s) 3 mL plasma collected in a 3.2% sodium citrate (light blue-top) tube

Causes for rejection

Gross hemolysis • Grossly lipemic

Alternative specimen(s)

Serum

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 86146

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation