Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Antiphospholipid Antibody Panel

Antiphospholipid Antibody Panel: Quest Diagnostics test 14890

Quest Diagnostics test 14890, CPT 83516, 86146, 86147. Specimen: 1 mL plasma collected in each of two 3.2% sodium citrate (light blue-top) tubes.

Antiphospholipid Antibody Panel is Quest Diagnostics test code 14890, billed with CPT 83516, 86146, 86147. Specimen: 1 mL plasma collected in each of two 3.2% sodium citrate (light blue-top) tubes. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), ARUP Laboratories, Cleveland Clinic Laboratories, Labcorp.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code14890
CPT86146 (x3), 86147 (x3), 83516 (x2)
LOINC—
Specimen1 mL plasma collected in each of two 3.2% sodium citrate (light blue-top) tubes
Minimum volume0.5 mL each specimen
ContainerTransport tube(s) Transport temperature Room temperature

Also known as: APS; Cardiolipin Ab

Methodology

Immunoassay (IA)

Collection instructions

Plasma (preferred): Centrifuge light blue-top tube 15 minutes at approximately 1500 x g within 60 minutes of collection. Using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic vial. Centrifuge a second time and transfer platelet-poor plasma into a new plastic vial. Plasma must be free of platelets (<10,000/mcL). Serum: Centrifuge a red-top tube (no gel) or serum separator tube 15 minutes at approximately 1500 g within 24 hours of collection. Transfer serum into a plastic specimen vial.

Stability

TemperaturePeriod
Room temperature5 days
Refrigerated14 days
Frozen30 days

Causes for rejection

Gross hemolysis • Grossly lipemic

Reference range

See individual tests

Alternative specimen(s)

Serum collected in each of two separate tubes

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 83516, 86146, 86147

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation