Sound Lab Consultants › National Lab Test Directory › Labcorp › β2-Glycoprotein 1 Antibodies, IgA

β2-Glycoprotein 1 Antibodies, IgA: Labcorp test 163900

Labcorp test 163900, CPT 86146. Specimen: Serum. Turnaround: 2 - 4 days.

β2-Glycoprotein 1 Antibodies, IgA is Labcorp test code 163900, billed with CPT 86146. Specimen: Serum. Turnaround time: 2 - 4 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Quest Diagnostics, ARUP Laboratories, Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code163900
CPT86146
LOINC21108-6
SpecimenSerum
Volume1 mL
Minimum volume0.5 mL
ContainerRed-top tube or gel-barrier tube
Turnaround time2 - 4 days
Storage / transportRoom temperature

Test includes

This test includes semiquantitative results for IgA antibodies against β 2 -glycoproteins.

Use

Anti-β2-glycoprotein I (anti-β2GPI) IgA antibody testing is used as a supplemental laboratory assessment in selected patients undergoing evaluation for antiphospholipid syndrome (APS), particularly when conventional antiphospholipid antibody (aPL) testing is negative despite persistent clinical suspicion for APS. Anti-β2GPI IgA antibodies may be useful in patients with unexplained arterial or venous thrombosis, pregnancy morbidity, systemic autoimmune disease (especially systemic lupus erythematosus) or features consistent with so-called “seronegative” APS.

Methodology

Thermo Fisher EliA™ automated FEIA-based autoantibody test

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x5
TemperaturePeriod
Room temperature7 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x5
TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x5

Reference range

β2-Glycoprotein 1 Antibodies, IgA: 0.0–9.5 EliA U/mL

Limitations

Current international APS classification criteria recognize only lupus anticoagulant (LA), anticardiolipin (aCL) IgG/IgM and anti-β2GPI IgG/IgM antibodies as laboratory criteria. Consequently, anti-β2GPI IgA antibodies are not included in the 2023 ACR/EULAR APS classification criteria and should be considered an adjunctive rather than primary diagnostic assay. Nevertheless, contemporary guidance acknowledges that IgA testing may provide clinically useful information in carefully selected patients when conventional laboratory criteria antibodies are absent. Anti-β2GPI IgA antibody testing should not be used as a stand-alone screening test for APS. Results must be interpreted in conjunction…

LOINC map

Result codeResult nameUnitsResult LOINC
163899Beta-2 Glycoprotein I Ab, IgAEliA U/mL21108-6

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86146

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation