Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Coxiella burnetii DNA, Qualitative Real-Time PCR

Coxiella burnetii DNA, Qualitative Real-Time PCR: Quest Diagnostics test 16596

Quest Diagnostics test 16596, CPT 87798. Specimen: 0.7 mL serum or CSF or bronchial alveolar lavage (BAL) collected in a sterile container.

Coxiella burnetii DNA, Qualitative Real-Time PCR is Quest Diagnostics test code 16596, billed with CPT 87798. Specimen: 0.7 mL serum or CSF or bronchial alveolar lavage (BAL) collected in a sterile container. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories, ARUP Laboratories, Labcorp.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code16596
CPT87798
LOINC—
Specimen0.7 mL serum or CSF or bronchial alveolar lavage (BAL) collected in a sterile container
Minimum volume0.3 mL
ContainerSterile container
Storage / transportSerum, CSF, BAL, whole blood: Refrigerated (cold packs) Tissue: Frozen

Methodology

Real-Time Polymerase Chain Reaction

Collection instructions

Tissue should be frozen on dry ice and transported frozen via overnight express. All other specimens should be transported refrigerated (2-8° C) via overnight express.

Stability

TemperaturePeriod
Room temperature48 hours
Refrigerated7 days
Frozen30 days

Reference range

Not detected

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering. Please provide Service area information to confirm Test Code for the lab that services your account.

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Alternative specimen(s)

Whole blood collected in: EDTA (lavender-top) tube or ACD (yellow-top) tube • Tissue collected in a sterile container

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 87798

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation