Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Babesia sp., DNA, PCR

Babesia sp., DNA, PCR: Labcorp test 138318

Labcorp test 138318, CPT 87798. Specimen: Whole blood. Turnaround: 3 - 4 days.

Babesia sp., DNA, PCR is Labcorp test code 138318, billed with CPT 87798. Specimen: Whole blood. Turnaround time: 3 - 4 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories, Quest Diagnostics.
LaboratoryLabcorp
CLIA number34D0655059
Test code138318
CPT87798
LOINC42641-1
SpecimenWhole blood
Volume0.5 mL
Minimum volume0.2 mL (Note: This volume does not allow for repeat testing.)
ContainerLavender-top (EDTA) tube or yellow-top (ACD) tube
Turnaround time3 - 4 days
Storage / transportRefrigerate.

Also known as: Babesia , DNA; Babesia , PCR

Test includes

Babesia microti

Use

This test is intended to be used as an aid in the diagnosis of Babesia species infection.

Methodology

Real-time polymerase chain reaction (PCR)

Stability

TemperaturePeriod
Room temperature7 days
Refrigerated7 days
FrozenUnstable
Freeze/thaw cyclesUnstable

Causes for rejection

Extensive hemolysis; lipemia; clotted specimen; quantity not sufficient for analysis; gross specimen contamination; specimen too old; leaking or broken tube

Limitations

This test is intended to detect Babesia microti , the primary etiologic agent of human babesiosis in the United States. Cross-reactivity may occur with other human pathogenic species, such as Babesia duncani (WA-1), Babesia divergens and Babesia MO-1. Alternate approaches, such as organism-specific serologic testing, should be considered if a definitive identification is required. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
139153Babesia sp., DNA, PCR42641-1

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 87798

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation