Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Bordetella pertussis/parapertussis DNA, Qualitative, Real-Time PCR

Bordetella pertussis/parapertussis DNA, Qualitative, Real-Time PCR: Quest Diagnostics test 11365

Quest Diagnostics test 11365, CPT 87798. Specimen: Nasopharyngeal aspirate or nasopharyngeal swab.

Bordetella pertussis/parapertussis DNA, Qualitative, Real-Time PCR is Quest Diagnostics test code 11365, billed with CPT 87798. Specimen: Nasopharyngeal aspirate or nasopharyngeal swab. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories, ARUP Laboratories, Labcorp.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code11365
CPT87798 (x2)
LOINC—
SpecimenNasopharyngeal aspirate or nasopharyngeal swab
ContainerNasopharygeal aspirate in a sterile vial or nasopharyngeal swab in Amies liquid (red-cap) medium
Storage / transportRefrigerated (cold packs)

Also known as: Whooping Cough

Methodology

Real-Time Polymerase Chain Reaction (PCR) This test detects but does not distinguish between B. Pertussis and B. Holmesii.

Collection instructions

Nasopharyngeal aspirates: Instill 1-1.5 mL of nonbacteriostatic saline (pH 7.0) into one nostril. Flush a plastic catheter or tubing with 2-3 mL of saline. Insert the tubing into the nostril parallel to the palate. Aspirate nasopharyngeal secretions. Repeat this procedure for the other nostril. Combine aspirates into a sterile vial. Nasopharyngeal swab: Collection kits using Amies liquid, M4, VCM/UTM are acceptable. Swab tips may be polyester, rayon, nylon flocked. Flexible shafts must be used for proper collection. Accuracy of the test depends on the collection of ciliated epithelial cells material. Half the distance from the nostril to the base of the ear could be used as estimation of the site of collection. Gently insert swab into the nostril. Keep the swab near the septum floor of the nose while gently pushing into the posterior nasopharynx. Rotate swab 2-3 times and hold in place for a few seconds for optimal collection. Collection of both nostrils is recommended but not required.

Stability

Nasopharyngeal aspirate Room temperature: 48 hours Refrigerated: 8 days Frozen: 30 days Nasopharyngeal swab Room temperature: 7 days Refrigerated: 7 days Frozen: 30 days

Causes for rejection

Collection tubes with Amies gel or charcoal containing media • Samples collected using cotton or calcium alginate tipped swabs • Rigid shaft swabs

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Alternative specimen(s)

Nasopharyngeal swab submitted in a VCM medium (green-cap) tube or equivalent UTM • Multi Microbe Media (M4) • eSwabs Minimum volume

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 87798

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation